Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
A multiwavelength photoplethysmography dataset with blood pressure and heart rate reference measurements
Elisabetta Leogrande1, Chiara Botrugno1, Giulio Trono2,3
1Department of Electrical and Information Engineering, Polytechnic University of Bari, Bari, 70126, Italy.
Abstract:
We present a dataset of photoplethysmographic (PPG) signals acquired from 127 seated subjects under controlled conditions. The signals were recorded using the MAX86150EVSYS, a commercial multiwavelength optical sensor capable of simultaneous acquisition at red and infrared wavelengths. Each signal was sampled at 100 Hz, following a standardized protocol that was formally reviewed and approved by the institutional ethics committee of Ospedali Riuniti di Foggia for biomedical data collection. In addition to the PPG waveforms, reference values of systolic and diastolic blood pressure, as well as heart rate, were obtained using a commercial sphygmomanometer. All measurements were performed while minimizing motion to ensure high-quality signals suitable for physiological modeling and algorithm development. This dataset is intended to support research in blood pressure estimation, PPG signal analysis, and the development of robust cardiovascular monitoring techniques for wearable health technologies. All data were collected with informed consent and in accordance with institutional ethical guidelines.
Related Concept Videos
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.