Related Experiment Video
Updated: Jan 9, 2026

Functional Isolation of Single Motor Units of Rat Medial Gastrocnemius Muscle
Published on: December 26, 2020
Discharge characteristics of motor units in FDI vary with load compliance but comprise a single neural module during
Logan E Weinman1, Kelsey Koger1, Nicholas Toninelli1
1Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States.
Abstract:
The purpose of our study was to determine the influence of load compliance on the discharge characteristics of the same motor units in the first dorsal interosseus (FDI) muscle during submaximal isometric contractions. Motor unit activity in FDI was recorded using high-density, surface electromyography while participants performed isometric contractions either by pushing against a rigid force transducer (force task) or supporting an equivalent inertial load (position task). The coefficient of variation for force decreased as the target force increased from 10% to 30% of maximal FDI force (index finger abduction) during the force task, whereas the standard deviation (SD) of acceleration increased with corresponding loads during the position task (both P < 0.001). The variability in discharge rate was greater during the position task and at the higher target (P < 0.001). There were two main findings: 1) factor analysis of the smoothed discharge rates yielded one motor unit mode for both compliance tasks and the two target forces, and 2) the SD of the discharge rates for the motor units included in the mode were more correlated with fluctuations in force or acceleration (0.52-0.84) than was the SD of the cumulative spike train (0.48-0.76). The emergence of a single motor unit mode for both tasks suggests that load compliance did not have a significant influence on the distribution of shared synaptic input to the involved motor neurons at either target force.NEW & NOTEWORTHY Although load compliance influences the discharge characteristics of the same motor units in first dorsal interosseus (FDI) during submaximal isometric contractions, most of the variance in discharge rate across conditions is explained by a single neural module (motor unit mode). Moreover, the first motor unit mode for the tracked motor units was more correlated with fluctuations in force (force task) or acceleration (position task) than was the cumulative spike train.
More Related Videos
08:41Dissection of Single Skeletal Muscle Fibers for Immunofluorescent and Morphometric Analyses of Whole-Mount Neuromuscular Junctions
Published on: August 14, 2021
13:07Simultaneous Intracellular Recording of a Lumbar Motoneuron and the Force Produced by its Motor Unit in the Adult Mouse In vivo
Published on: December 5, 2012
Related Concept Videos
Motor Units
Motor units come in different sizes, with smaller units...
Motor Units
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Excitation-Contraction Coupling in Skeletal Muscles
When an action...
Types of Skeletal Muscle Fibers
Fast-twitch fibers
Fast-twitch fibers, or Type II fibers, are designed for quick, powerful bursts of speed and strength. They reach peak tension within approximately 0.01 seconds following stimulation. Characterized by a large diameter and densely packed myofibrils, these fibers contain...