Short-term effects of positive end-expiratory pressure titration strategies on lung clinical markers in COVID-19: A randomized controlled trial
Related Experiment Video
Updated: Jan 9, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Wagner Souza Leite1, Shirley Lima Campos2, Caio César Araújo Morais3
1Graduate Program in Applied Health Biology, Federal University of Pernambuco, Recife, Pernambuco, Brazil.
Background:
Severe acute respiratory failure from COVID-19 is associated with high mortality. Optimal positive end-expiratory pressure (PEEP) titration is essential for lung-protective ventilation; however, different strategies may elicit distinct clinical responses.
Objective:
To compare the short-term effects of three PEEP titration strategies on lung injury score (LIS), changes in oxygenation, respiratory mechanics, and electrical impedance tomography (EIT) measures in mechanically ventilated patients with COVID-19.
Methods:
In this randomized, parallel-group trial, 75 intubated patients were randomly assigned to EIT-guided PEEP (PEEP-EIT), driving pressure-guided PEEP (PEEP-DP), or ARDSNet-based PEEP (PEEP-ARDSNet). Primary outcome was change in lung injury score (LIS); secondary outcomes included PaO₂/FiO₂ ≥ 150 mmHg, PaO₂/FiO₂ response ≥ 20 mmHg, driving pressure reduction, compliance increase, EIT-based regional ventilation and aeration, and adverse events within a four-hour follow-up.
Results:
Mean PEEP levels differed across groups: PEEP-EIT (13.3 cmH₂O), PEEP-DP (10.6 cmH₂O), and ARDSNet (12 cmH₂O). PEEP-EIT showed greater LIS reduction (ORweighted 3.7, 1.58 - 8.57; p = 0.004) and higher odds of oxygenation response vs. PEEP-DP (ORweighted 4.2, 2.15 - 8.27; p < 0.01) and PEEP-ARDSNet (ORweighted 3.6, 1.8- 7.1; p < 0.001). Both PEEP-EIT and PEEP-DP significantly improved driving pressure (PEEP-EIT: ORweighted 6.6, 2.6- 17.07; PEEP-DP: ORweighted 7.02, 2.7 - 18.2) and compliance (PEEP-EIT: ORweighted 9.5, 3.7- 24.33; PEEP-DP: ORweighted 5.94, 2.28 - 15.5) compared to PEEP-ARDSNet (p < 0.001 for both comparisons). No adverse events related to PEEP titration were reported.
Conclusion:
EIT-guided PEEP titration outperformed ARDSNet and DP-guided strategies in reducing lung injury and improving compliance and oxygenation in patients with COVID-19.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pneumonia IV: Management
Bacterial Pneumonia Treatment
For bacterial pneumonia, antibiotics serve as the cornerstone of therapy. Initial treatment often begins with empirical antibiotics, tailored to the anticipated causative organism and adjusted based on culture results. Key antibiotic choices include:
COPD: Management Using Bronchodilators and Corticosteroids
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...