Related Experiment Video
Updated: May 9, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Evaluation of Angle Changes in Reverse Margin Abutments on Excess Cement: A Comparison With Standard Implant Abutment
Abstract:
Dental implants are widely used for treating edentulism, but peri-implant diseases pose a challenge to their success. Excess cement in the gingival sulcus is a significant risk factor for these conditions. Reverse margin abutments have been suggested to minimize excess cement and related risks. This study aims to evaluate the effect of different reverse angles in abutments on reducing excess cement in the gingival sulcus. In this in vitro study, 3 abutments were designed using Solidworks Premium 2023 software: 1 with a chamfer margin and 2 with reverse margins at 30° and 45° angles. Each group consisted of 10 samples (n = 10). The abutments were fabricated using Ti-6Al-4V alloy via 3D printing. Crowns for the maxillary first molar were designed using computer-aided design/computer-aided manufacturing technology and made from zirconia. Thirty fixtures from the Straumann bone-level implant system (GH = 2, diameter 4.5 mm) were mounted in acrylic blocks, and the abutments were positioned on the fixtures. Temp-Bond temporary cement was applied under a pressure of 4 kg. After the cement had set, photographs were taken and analyzed using Adobe Photoshop 2024. The cement extension beyond the margin was quantified in both millimeters and pixels. Data were analyzed using Kruskal-Wallis and Mann-Whitney tests (α = .05). The abutment with a chamfer margin directed the cement toward the apical region, whereas the abutments with reverse margins pushed the cement outside the tissue. The reverse margin abutment with a 30° angle showed a significantly lower excess cement than the chamfer margin abutment (P = .013). Similarly, the reverse margin abutment with a 45° angle had significantly less excess cement than the chamfer margin abutment (P < .001). There was no statistically significant difference between the reverse margin abutments at 30° and 45° angles (P > .05). Using reverse margin abutments instead of chamfer margin abutments significantly reduced the remaining excess cement in the gingival sulcus. However, altering the angle of the reverse margin from 30° to 45° does not significantly impact the overall amount of residual cement.
Related Concept Videos
Testing Water Quality
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Water Cement Ratio
Impact Strength of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Design Example: Maintaining Level of an Embankment

