Image-guided intensity-modulated radiotherapy with reduced margins in patients with prostate cancer: Results of the
Olivier Riou1, Pascal Fenoglietto2, Marta Jarlier3
1Department of Radiation Oncology, Montpellier Cancer Institute (ICM), University of Montpellier, Montpellier, France; Inserm U1194, Montpellier Cancer Research Institute (IRCM), University of Montpellier, Montpellier, France; University Federation of Radiation Oncology of Mediterranean Occitanie, Montpellier, France.
Background And Purpose:
Intensity-modulated (IMRT) and image-guided (IGRT) radiotherapies reduce radiation-induced toxicities in localized prostate cancer. This randomized phase II trial (NCT03254420) evaluated late pelvic toxicity (LPT) and quality of life after IMRT/IGRT with standard or reduced margins in patients with low- to intermediate-risk prostate cancer.
Materials And Methods:
Between August 2016 and May 2022, 74 patients were randomized (1:2) to IMRT/IGRT with standard (Control, n = 30) or reduced (Experimental, n = 44) margins. Control IGRT used cone-beam computed tomography (CBCT), while experimental IGRT combined CBCT with real-time tracking (Calypso® 4D Localization System) and smaller margins. Prostate margins were 3 mm in the Experimental arm versus 1 cm (0.5 cm posteriorly) in the Control arm. The primary endpoint was grade ≥ 2 LPT (CTCAE v4.03). Toxicities were assessed by physician-scored CTCAE and patient-reported quality-of-life outcomes.
Results:
Grade ≥ 2 LPT occurred in 5 patients in each arm. Over the study period, 88.6 % (95 % CI: 75.4-96.2) of patients in the Experimental arm and 80.8 % (95 % CI: 60.6-93.4) in the Control arm did not experience a grade ≥ 2 LPT. Under conventional fractionation, the Experimental arm had significantly lower rectal (V70Gy, D50%) and bladder (D50%, V70Gy, V76Gy) doses (p < 0.01), but higher rectal (D1%, V76Gy) and bladder (V80Gy) doses (p < 0.01). At two years post-radiotherapy, urinary symptom scores were significantly lower in the Experimental arm (mean 12.3 vs. 21.2, p = 0.028).
Conclusion:
IMRT/IGRT with reduced margins is feasible and may improve some dosimetric outcomes. Both arms had low LPT rates, but reduced margins may improve patient-reported urinary symptoms.