A conformal piezoelectric microsystem for demographic-adaptive and calibration-free cuffless blood pressure
Cunman Liang1,2,3, Zhou Jiang1,2,4, Shirong Qiu1
1Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China.
Abstract:
Frequent recalibration poses a significant challenge to the accuracy and reliability of current cuffless blood pressure (BP) monitoring devices, especially in long-term use. Here, we introduce a conformal and stretchable piezoelectric microsystem (CSPM) combined with a demographic-adaptive BP estimation model, enabling calibration-free, continuous BP tracking with accuracy comparable to cuff-based medical devices. The CSPM integrates an ultrasound transducer array for vessel diameter waveform recording and two pulse waveform (PWF) sensors with cavity-enhanced piezoelectric thin films for precise pulse wave detection, enabling simultaneous measurement of pulse wave velocity (PWV) and vessel diameter in the same localized vascular area. Leveraging real-time PWV and vessel diameter inputs, our BP algorithm employs a demographic feature learning module for broad population applicability and a time decay compensation strategy to address minor slippage and measurement shifts, enabling the acquisition of individual BP values without calibration. This innovation effectively addresses key challenges in population recalibration and multimodal integration, enabling stable long-term continuous BP tracking, achieving mean absolute errors of 5.22 mmHg for systolic BP and 4.57 mmHg for diastolic BP.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure