Related Experiment Video
Updated: Jan 9, 2026

A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
Published on: November 13, 2016
Comparison of the SeizCT Primer and Optimized Models for Predicting Positive Computed Tomography Findings in Patients
Natthaphon Pruksathorn1, Thanin Lokeskrawee1, Jarupa Yaowalaorng1
1Department of Emergency Medicine, Lampang Hospital, Mueang District, Lampang 52000, Thailand.
Background:
Previous studies developed the SeizCT primer and optimized models, both demonstrating similar values for the area under the receiver operating characteristic curve (AuROC). The optimized model incorporates Glasgow Coma Scale (GCS) change from baseline instead of categorized GCS at emergency department (ED) presentation. This study aimed to validate these two models for predicting positive computed tomography (CT) findings in patients with non-traumatic seizures.
Methods:
A retrospective cross-sectional study was conducted among adult patients (≥ 18 years) with non-traumatic seizures who underwent CT brain imaging in the ED at Lampang Hospital. Data were collected between December 2023 and July 2024 based on parameters from the SeizCT primer and optimized models. External validation compared model performance using AuROC, calibration, decision curve analysis (DCA), and confusion matrices.
Results:
The validation cohort included 312 patients (210 (67.3%) male; mean age 53 years). Positive CT findings were found in 58 patients (18.6%). The SeizCT primer model had an AuROC of 0.7218 (95% confidence interval (CI): 0.6476, 0.7961), while the SeizCT optimized model achieved 0.7394 (95% CI: 0.6663, 0.8124). An equivalence test showed statistically equivalent discrimination between the two models (P < 0.015), with the optimized model demonstrating better calibration (slope: 0.582 vs. 0.701; P = 0.002; observed-to-expected ratio: 0.934 vs. 0.971; P = 0.030).
Conclusions:
Both models demonstrated fair to acceptable discrimination after external validation. The SeizCT optimized model is recommended, as it showed superior calibration and its incorporation of GCS change from baseline offers greater clinical applicability.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...