A high transmission tender X-ray monochromator employing a matched pair of multilayer grating and mirror
David Dennetiere1, Thierry Moreno1, Blandine Capitanio1
1Synchrotron Soleil, L'Orme des Merisiers, Départementale 128, 91190 Saint-Aubin, France.
Abstract:
It is now well established that multilayer coated gratings may offer high diffraction efficiencies over the tender X-ray range, from about 1 keV to 5 keV, covering the gap between single layer coated grating monochromators and crystal monochromators. Nevertheless, few beamlines in the world are using such gratings in their monochromator. The successful implementation of a multilayer grating monochromator requires producing a matched pair of a multilayer grating and a multilayer mirror, and this matching is not straightforward as it must account for different incidence angles and refraction effects on each element. Here we review the realization of the multilayer grating monochromator of the SIRIUS beamline which has been successfully in service for several years. We show how, by alternating computer simulation with our diffraction code and measurements, we could optimize the monochromator transmission on a very wide energy range. After the grating was coated, it was found that the angle of optimal efficiency versus photon energy was significantly different from what was predicted by a simple conformal model of binary layers. Layer interdiffusion and profile smoothing during the deposition process must be added to the multilayer model to reproduce the measured data. The critical adjustment of the mirror multilayer period is achieved by the lateral translation of the mirror, which was given a small transverse period gradient. The monochromator is thus providing high transmission efficiency in the 1 to 5 keV energy range, more than 30% over 2.5 keV and up to 46% at 4.6 keV.
Related Concept Videos
IR Spectrometers
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Transmission Electron Microscopy