Related Experiment Video
Updated: Jul 4, 2026

Visualization of Flow Field Around a Vibrating Pipeline Within an Equilibrium Scour Hole
Published on: August 26, 2019
AI-guided real-time detection of flow irregularities and bottlenecks in pharmaceutical vial filling lines using
Sai Vijay Thattukolla1, Sai Vinay Thattukolla2
1CSL Behring, Chicago, Illinois, USA.
Aim/Background:
Ensuring smooth and consistent vial flow on pharmaceutical filling line conveyors is essential for maintaining sterility, reducing downtime, and avoiding costly disruptions. However, irregular vial movement such as spacing gaps, clustering, and vial flipping is often seen, leading to filling delays, broken glass, machine stoppages, and extended batch times. Existing systems lack the ability to detect such irregularities in real time and provide actionable alerts.
Materials And Methods:
A lightweight, AI-guided framework was developed for detecting vial flow irregularities and classifying bottleneck risks using computer vision. A high-speed camera positioned above the conveyor captured video frames processed by YOLOv8 for real-time object detection. OpenCV was used to extract vial positions and calculate flow metrics (average spacing, standard deviation, inter-vial gap thresholds). A rule-based classification system assigned bottleneck risk levels: low, medium, or high. Operational conveyor footage from a pharmaceutical filling line was analyzed; to protect confidentiality, frames were de-identified and re-rendered as schematic visualizations that preserve vial geometry and spacing statistics.
Results:
Across 15 operational frames, the classifier achieved an accuracy of 93.3%, F1-macro 95.21%. On throughput, the end-to-end pipeline processed frames at ∼18 FPS on CPU and ∼25 FPS on Jetson Nano. Detector evaluation yielded mAP@0.5 = 100.00%, mAP@[0.5:0.95] = 70.09%, precision = 98.65%, recall = 100.00%, F1 = 99.32% at confidence 0.50.
Conclusion:
This scalable, non-invasive solution can be integrated into existing pharmaceutical lines to improve operational efficiency and product integrity. The rule-based approach offers interpretability, making it suitable for GMP-regulated environments. Across the operational validation set, the risk classifier achieved macro average precision of 95.24%, recall of 95.83%, and F1 of 95.21%.
More Related Videos
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
05:47Simulation of a Scaled Assembly Process with Collaboration of a Robotic Arm and Monitoring through a Vision System for Quality Control
Published on: August 29, 2025
Related Concept Videos
Compartment Models: Single-Compartment Model
Modified-Release Drug Delivery Systems: Rate-Programmed I
Pipe Flowrate Measurement: Problem Solving