Related Experiment Video
Updated: Jan 9, 2026

Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Assessment of Relationship Between Temperature and Selected Technical Parameters of High-Strength, Fine-Grained
Tomasz Drzymała1, Bartosz Zegardło2, Krzysztof Przystupa3
1Faculty of Safety Engineering and Civil Protection, Fire University, 52/54 Słowackiego Street, 01-629 Warsaw, Poland.
Abstract:
Cement composites are non-flammable, and their resistance to high temperatures is only apparent. This article presents extensive research on the strength parameters of building mortars exposed to fire-simulating conditions. The analyses included assessment of the mortars' tensile, compressive and flexural strength, as well as their flexural modulus of elasticity. Microscopic analysis of the samples was performed using a scanning electron microscope (SEM). The results of optimisation studies, particularly tensile strength tests conducted for various types of additives (fibres), showed that the addition of polypropylene fibres had a beneficial effect across the entire temperature range. Based on the research, relationships between temperature and the tested parameters were developed. Polynomial models were applied for their approximation, with the selection justified both by the high consistency with the experimental results and by the nature of the physical changes occurring in the cement mortar during subsequent stages of heating. These models allow an approximate assessment of the condition of mortar after a fire. Based on the conducted microstructural analyses of mortars and their correlation with the strength test results, graphical models were presented to illustrate the phenomena governing the changes in the examined parameters at various fire temperatures. On the basis of conclusions drawn from the analyses, recommendations were formulated regarding the use of polypropylene fibres in selected structural elements that may be exposed to fire, and the limitations of their applicability were indicated.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Related Concept Videos
Mortar Properties
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Brick Durability, Strength, and Appearance
Mortar Joint Deterioration in Masonry