Related Experiment Video
Updated: Jan 9, 2026

Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
Published on: January 5, 2014
A 0.6-V All-Digital Temperature Sensor with Reduced Supply Sensitivity
Hui Zhou1, Yi Wang1, Shuang Xie1,2,3
1School of Integrated Circuits, Shandong University, Jinan 250100, China.
None:
The present work introduces a 0.6-volt, all-digital, synthesizable temperature sensor characterized by reduced sensitivity to supply voltage variations. The design incorporates two distinct logic delay lines that are distinguished by their equivalent transistor lengths. These variations in transistor lengths result in varying threshold voltages and thermal dependencies. The difference in thermal dependency is detected through the ratio of their charging currents, which are subsequently transformed into digital outputs via their propagation delays. By employing two types of delay lines, the sensor achieves an eightfold reduction in power supply sensitivity compared to configurations utilizing a single delay line and also obviates the necessity for an external clock. Fabricated with 55 nm CMOS technology, the proposed sensor exhibits an inaccuracy of ±1 °C, evaluated through global linear fitting and two-point calibration across five chips, within a temperature range of 20 to 90 °C. The all-digital temperature sensor consumes 2 nanojoules (nJ) for each conversion, with a conversion duration of 0.8 milliseconds (ms) and a resolution of 0.2 °C. The prototype's physical dimensions are 37 × 31 μm2. Additionally, synthesis on a Cyclone IV FPGA reveals similar characteristics in terms of supply sensitivity reduction.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...