Application of the Akaike Information Criterion to Ultrasonic Measurement of Liquid Volume in a Cylindrical Tank
Krzysztof J Opieliński1, Tomasz Świetlik1
1Department of Acoustics, Multimedia and Signal Processing, Faculty of Electronics, Photonics and Microsystems, Wroclaw University of Science and Technology, Wybrzeże Stanisława Wyspiańskiego 27, 50-370 Wrocław, Poland.
Abstract:
The ultrasonic sensor method is the most significant and widely accepted technique for measuring liquid levels in tanks. Ultrasonic waves are particularly advantageous in the case of explosive, flammable, or aggressive liquids because of the possibility of introducing ultrasonic pulses through the tank wall safely. Often, the measurement of these liquids should be performed automatically using electronic devices to ensure that the tank remains sealed. In the case of ultrasound, measurements are made using the echo method, with a transmitting-receiving (transceiver) ultrasonic transducer that sends vibration pulses into the tank. The measured delay between the transmitted pulse and the pulse reflected from the liquid surface is proportional to the liquid level in the tank. The volume of liquid can be calculated on the basis of the dimensions of the tank. In this method, it is very important to accurately determine the delay by detecting the beginning of the reflected pulse, which determines the accuracy of the measurement of the level of the liquid and its quantity in the tank. To improve this accuracy, this paper proposes the use of the Akaike Information Criterion (AIC) used in statistics for model selection. As part of the research, ultrasonic test measurements were performed for a tank filled with water and extraction gasoline. This allowed a favorable comparison of the AIC method with the most commonly used threshold method and for determining the accuracy of liquid volume measurements in the tank using both methods in relation to the parameters of several selected ultrasonic sensors. The accuracy obtained using the AIC method was found to be better than that of the fixed-fractional amplitude threshold method. Furthermore, the AIC method is more versatile because it is less sensitive to interference and is capable of detecting the onset of a pulse regardless of its shape and frequency, even in noise. It is suitable for real-time embedded systems for liquid level measurement as well.
Related Concept Videos
Deriving the Speed of Sound in a Liquid
The speed of sound in fluids can be derived by considering a mechanical wave...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Uncertainty in Measurement: Reading Instruments
Pipe Flowrate Measurement: Problem Solving