Related Experiment Video
Updated: Jan 9, 2026

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
Assessment of Seismic Performance and Structural Health Monitoring of a Retrofitted Reinforced Concrete Structure
Theodoros Rousakis1, Vachan Vanian1, Martha Lappa1
1Department of Civil Engineering, Democritus University of Thrace, 67100 Xanthi, Greece.
Abstract:
This study examines Phase B of the GREENERGY project focusing on the seismic performance and structural health monitoring of a renovated single-story RC frame with brick masonry infills that received significant strategic structural interventions. The columns were confined with basalt fiber ropes (FR, 4 mm thickness, two layers) in critical regions, the vertical interfaces between infill and concrete were filled with polyurethane PM forming PUFJ (PolyUrethane Flexible Joints), and glass fiber mesh embedded in polyurethane PS was applied as FRPU (Fiber Reinforced PolyUrethane) jacket on the infills. Further, greenery renovations included the attachment of five double-stack concrete planters (each weighing 153 kg) with different support-anchoring configurations and of eight steel frame constructions (40 kg/m2) simulating vertical living walls (VLW) with eight different connection methods. The specimen was subjected to progressively increasing earthquake excitation based on the Thessaloniki 1978 earthquake record with peak ground acceleration ranging from EQ0.07 g to EQ1.40 g. Comprehensive instrumentation included twelve accelerometers, eight draw wire sensors, twenty-two strain gauges, and a network of sixty-one PZTs utilizing the EMI (Electromechanical Impedance) technique. Results demonstrated that the structure sustained extremely high displacement drift levels of 2.62% at EQ1.40 g while maintaining structural integrity and avoiding collapse. The PUFJ and FRPU systems maintained their integrity throughout all excitations, with limited FRPU fracture only locally at extreme crushing zones of two opposite bottom bricks. Columns' longitudinal reinforcement entered yielding and strain hardening at top and bottom critical regions provided the FR confinement. VLW frames exhibited equally remarkably resilient performance, avoiding collapse despite local anchor degradation in some investigated cases. The planter performance varied significantly, yet avoiding overturning in all cases. Steel rod anchored planter demonstrated superior performance while simply supported configurations on polyurethane pads exhibited significant rocking and base sliding displacement of ±4 cm at maximum intensity. PZT structural health monitoring (SHM) sensors successfully tracked damage progression. RMSD indices of PZT recordings provided quantifiable damage assessment. Elevated RMSD values corresponded well to visually observed local damages while lower RMSD values in columns 1 and 2 compared with columns 3 and 4 suggested that basalt rope wrapping together with PUFJ and FRPU jacketed infills in two directions could restrict concrete core disintegration more effectively. The experiments validate the advanced structural interventions and vertical forest renovations, ensuring human life protection during successive extreme EQ excitations of deficient existing building stock.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Prestressed Concrete
Reinforced Brick Masonry
To fortify brick walls...
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Non-destructive Tests for Concrete Strength
Workability of Concrete
Concrete's workability is determined by its resistance to internal forces that arise...