Related Experiment Video
Updated: Jan 9, 2026

High-throughput Identification of Bacteria Repellent Polymers for Medical Devices
Published on: November 5, 2016
A Novel SEM Image Processing Approach for Evaluating Sterilization Effects on Polymeric Medical Devices: Validation
Mohamed A Aboamer1, Rashed Almousa1, Ahmad Alassaf1
1Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia.
None:
This study aimed to evaluate the impact of UVC (Ultraviolet C Radiation), detergent foam, and alcohol (70%) sterilization methods on the surface morphology of acrylonitrile-butadiene-styrene (ABS) specimens using a novel SEM (Scanning Electron Microscope) image processing approach. Twelve 3D-printed specimens were prepared, and five concentric circular regions of interest (ROIs) per specimen were analyzed. Three quantitative descriptors-defect area fraction, anisotropy ratio, and RMS (Root Mean Square) roughness-were extracted to assess surface alterations. To validate the image-based findings, EDX (Energy-Dispersive X-ray Spectroscopy) elemental analysis for carbon (C), nitrogen (N), and oxygen (O) was employed as a complementary and traditional benchmark technique. Statistical comparisons and p-value heat maps revealed strong convergence between SEM and EDX results. UVC sterilization consistently preserved surface morphology and elemental stability, showing the lowest defect fraction (p = 0.2684), balanced anisotropy (p = 0.02481), and minimal oxygen incorporation (O = 7.6). Foam sterilization produced intermediate effects, with significant anisotropy changes (p = 0.007456) and reduced nitrogen (19.6). Alcohol sterilization induced the most severe damage, characterized by high defect density, increased roughness, and elemental imbalance (N = 17.3, O = 13.9), confirming oxidative degradation. The convergence of SEM and EDX outcomes demonstrates that SEM image processing is a reliable novel method validated by traditional elemental analysis. Together, these approaches provide a robust framework for ranking sterilization efficacy, with UVC identified as the most favorable method, detergent foam as an acceptable alternative, and alcohol as the least effective due to its destabilizing effects.
More Related Videos
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration