Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
2.5K
Concomitant Surgical Ablation Using a Novel Bipolar Radiofrequency Clamp: Outcomes from the TRAC-AF Registry
Christian Shults1, Armin Kiankhooy2, Shaf B Holden3
1MedStar Washington Hospital Center, Washington, DC 20010, USA.
Journal of Clinical Medicine
|December 11, 2025
Summary
Real-world evidence shows a novel bipolar radiofrequency clamp for epicardial left atrial encircling lesions during cardiac surgery is safe and effective for treating atrial fibrillation (AF). This surgical ablation technique achieved high freedom from AF/AT/AFL and favorable long-term survival rates.
Area of Science:
- Cardiology
- Cardiac Surgery
- Electrophysiology
Background:
- Surgical ablation for atrial fibrillation (AF) during cardiac surgery is a Class I recommendation due to improved patient outcomes.
- Evolving ablation tools include radiofrequency and cryothermal devices.
- This study evaluates real-world evidence (RWE) of a novel bipolar radiofrequency clamp for epicardial left atrial encircling lesions.
Purpose of the Study:
- To evaluate the safety and efficacy of concomitant surgical ablation using a novel bipolar radiofrequency clamp for an epicardial left atrial encircling lesion.
- To assess long-term rhythm outcomes and survival in patients undergoing this procedure.
Main Methods:
- Data from 327 patients with AF undergoing cardiac surgery were analyzed from the TRAC-AF Registry.
- Patients received an epicardial left atrial encircling lesion created by a novel bipolar radiofrequency clamp.
- Freedom from AF/AT/AFL and survival were evaluated using Kaplan-Meier analysis; safety was assessed within 30 days.
Main Results:
- One- and two-year survival rates were 95.3% and 88.1%, respectively.
- Freedom from AF/AT/AFL at 12 and 24 months was 87.4% and 79.9%, respectively.
- Thirty-day mortality was 1.5%, with no serious adverse events related to the ablation procedure or device.
Conclusions:
- RWE from the TRAC-AF Registry indicates that surgical ablation with an epicardial left atrial encircling lesion using a novel bipolar RF clamp is safe.
- The procedure resulted in favorable long-term rhythm outcomes and survival.