Summary
Using a slow-firing mode for powered staplers significantly reduced bleeding from pulmonary vessel stumps during thoracic surgery. This simple adjustment can improve staple-line security and reduce complications in patients undergoing pulmonary resections.
Area of Science:
- Thoracic Surgery
- Surgical Technology
- Vascular Surgery
Background:
- Central vascular stump oozing is a persistent challenge in thoracic surgery following pulmonary vessel stapling.
- Optimal firing speed for powered staplers to minimize bleeding is not well-established.
- This study investigates the efficacy of slow-firing mode versus fast-firing mode in reducing intraoperative stump oozing.
Purpose of the Study:
- To evaluate if slow-firing mode reduces intraoperative stump oozing compared to default fast-firing mode during pulmonary vessel stapling.
- To identify factors influencing stump oozing during powered stapling.
- To assess the impact of firing speed on hemostatic intervention needs and stapling time.
Main Methods:
- A retrospective two-center cohort study analyzed 276 pulmonary vessel stapling events using a powered stapler with adjustable firing speed.
- Patients were divided into slow-firing (168 events) and fast-firing (108 events) groups.
- Inverse probability of treatment weighting (IPTW) and multivariable logistic regression adjusted for confounders like vessel type, diameter, and mechanical stress.
Main Results:
- The overall incidence of stump oozing was 23.2%.
- Slow-firing mode showed a significantly lower incidence of oozing (17.9%) compared to fast-firing mode (31.5%; P=0.01).
- After IPTW adjustment, slow-firing mode was independently associated with reduced oozing risk (OR, 0.51; P=0.03), with pulmonary artery stapling, lifting, and traction identified as risk factors.
Conclusions:
- Slow-firing mode significantly decreases prolonged stump oozing from central vascular stumps, especially during pulmonary artery transection.
- This finding suggests slow-firing mode is a practical strategy to enhance staple-line security.
- Further validation in prospective studies is recommended to confirm these benefits.