Transformer maintenance strategy based on improved risk assessment method considering operation and maintenance costs
Hongbing Guo1, Yan Wang2, Hongbin Bo3
1Inner Mongolia Power (Group) Co., Ltd., Inner Mongolia Power Research Institute Branch, Hohhot, Inner Mongolia, China.
Abstract:
The rapid development of modern industry cannot be separated from the support of large power equipment such as transformers. Transformers need to maintain high reliability to provide power support, and adopting a reasonable maintenance strategy is one of the important methods to maintain high reliability. At present, maintenance strategy research around transformers mainly focuses on transformer groups, single equipment or components, and lacks specialized research on specific failure modes. The overall maintenance strategy had the problem of insufficient identification and prevention of specific failure, which led to insufficient focus on resource investment. Traditional risk analysis methods insufficiently consider some risk factors and weight allocation. Therefore, this study considers specific failure modes of transformers and obtains a cost-oriented maintenance strategy for failure modes based on an improved risk analysis method. This study provides a new method for maintenance management of transformers, which helps to allocate maintenance resources reasonably and reduce maintenance costs.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Transformers with Off-Nominal Turns Ratios
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...