Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Multi-sorbent passive sampler for the preconcentration of contaminants with broad polarity spectrum in drinking
Vincent Dufour1, Guilhem Zerbini1, Laure Wiest1
1Universite Claude Bernard Lyon 1, CNRS, ISA, UMR5280, 5 rue de la Doua, F-69100 Villeurbanne, France.
Abstract:
The occurrence of Persistent and Mobile Organic Contaminants (PMOCs), especially very polar compounds (log P <1), remains poorly characterized in drinking water due to analytical limitations. These compounds are highly soluble, weakly retained on conventional C18 materials, and may persist through treatment processes, raising concerns about potential health and environmental impacts. To address this challenge, we developed a passive sampler combining three complementary sorbents (HLB, SAX, and SCX) to enhance retention across a wide polarity range. The device was evaluated under controlled conditions (47 target substances, 3 concentrations, triplicates) to assess sorption performance and pH sensitivity. Results confirmed the complementarity of the sorbents with broad retention for HLB and more specific patterns for SAX and SCX. The tool was then deployed for 15 days in both raw and treated waters across seven drinking water treatment plants. A total of 37 contaminants were detected, including 20 with log P < 1. The treatment processes proved effective, with an average 13-fold reduction in the accumulated quantities between RW and TW, although the contamination profile in TW appeared more complex, likely reflecting presence of transformation products and residual highly polar compounds. Compounds with log P < 1 were found to pass more efficiently through drinking water treatment processes, consistent with their higher polarity and lower affinity for conventional removal pathways. By integrating exposure over time, the sampler lowered detection limits and offered a more exhaustive contamination profile. This approach supports improved PMOC surveillance and lays the groundwork for future quantitative or untargeted monitoring strategies in drinking water systems.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Analyte Adsorption and Distribution
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Precipitation and Co-precipitation
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors