Related Experiment Video
Updated: Jan 8, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
Published on: January 6, 2019
Non-contrast free-running high-resolution volumetric multi-slab cardiac cine MRI at 3 T
Chenhao Gao1, Fan Yang1, Zhihao Xue1
1National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
None:
Free-running self-gated 3D cardiac cine imaging is highly desirable for volumetric, high-resolution, breath-hold-free assessment of left ventricular (LV) function. However, its implementation at 3 T remains challenging due to specific absorption rate (SAR) constraints and reduced myocardium-blood contrast. In this study, we propose a novel non-contrast, free-running, self-gated 3D gradient-echo (GRE) cine sequence for 3 T imaging, which acquires multi-slab data using a pseudo-radial Cartesian trajectory with a 1.5 mm slice thickness. To address respiratory motion, a locally low-rank motion-corrected image reconstruction algorithm was developed. Fifteen participants underwent imaging with the proposed multi-slab 3D cine sequence and conventional 2D cine sequences. Additionally, single-slab 3D cine data were acquired in 10 participants. Various image quality metrics (signal-to-noise ratio, contrast-to-noise ratio, myocardial sharpness, and residual artefact) and LV volumetric parameters (end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF)) were compared between the different methods. Results demonstrated that the proposed multi-slab 3D cine method provided significantly superior image quality compared to the single-slab 3D approach (myocardial sharpness: 2.82 ± 0.42 vs. 1.58 ± 0.46, P = 0.005; residual artefact: 2.58 ± 0.26 vs. 1.13 ± 0.21, P = 0.005) due to the improvement of image contrast. Furthermore, the multi-slab 3D cine sequence exhibited good agreement and correlation with the reference 2D cine method in terms of volumetric measures (EDV: 140.3 ± 19.9 mL vs. 139.3 ± 20.0 mL, P = 0.357, r = 0.976; ESV: 56.7 ± 11.8 mL vs. 57.7 ± 10.2 mL, P = 0.259, r = 0.964; EF: 59.8 % ± 4.9 % vs. 58.7 % ± 3.7 %, P = 0.073, r = 0.907). In conclusion, the proposed multi-slab 3D cine framework enables free-running 3 T cine imaging with whole-heart coverage and high through-plane resolution. Although myocardium-blood contrast is reduced compared to 2D breath-hold cine, the retained contrast is sufficient to evaluate LV function.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

