NITINOL MATERIAL PROPERTIES OF 11 COMMERCIAL PERIPHERAL STENTS DETERMINED USING INVERSE COMPUTATIONAL ANALYSIS
Eric Anttila1, Kaspars Maleckis2, Majid Jadidi2
1Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE, USA.
None:
Stent-artery interactions are influenced by the mechanical properties of self-expanding Nitinol stents, but data on these characteristics remain limited. Eleven stents (Absolute Pro, S.M.A.R.T. Control, Misago, Zilver, Complete SE, EverFlex, Innova, Pulsar-18, LifeStent, S.M.A.R.T. Flex, and Supera) used to treat peripheral arterial disease (PAD) were subjected to axial tension, compression, three-point bending, and torsion tests, and the data on reaction forces and moments were compared with finite element simulations of the same experiments. Inverse computational analysis was used to determine austenite and martensite elasticity, transformation stretch, stresses at the start and end of transformation loading, and the start of transformation stress in compression. Uniaxial tensile tests were done on isolated struts from Absolute Pro and Zilver stents to verify the results of the inverse analysis. Our study demonstrate that Nitinol material properties are significantly different across devices. Austenite elasticity ranged 7.5-85 GPa, martensite elasticity 10-47.8 GPa, transformation stretch 1.03-1.08, the start of transformation loading stress 386-465 MPa, the end of transformation loading stress 411-535 MPa, and the start of transformation stress in compression 150-900 MPa. Nitinol of S.M.A.R.T. Control and S.M.A.R.T. Flex devices had the softest response, while Pulsar-18 had the hardest. The presented Nitinol mechanical properties of commonly used PAD stents can improve the fidelity of computational models investigating stent-artery interactions and may help improve clinical outcomes of endovascular PAD repairs through better device design.
Related Concept Videos
Properties of Organometallic Compounds
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...