Update and expansion of a system constant database for open-tubular columns used in gas chromatography
1Department of Chemistry, Wayne State University, Rm 185 Chemistry, Detroit, MI 48202, United States.
Abstract:
The solvation parameter model is used to characterize the retention properties of fused-silica, open-tubular columns precoated with poly(siloxanes) containing methyl, phenyl, 3,3,3-trifluoropropyl, and 3-cyanopropyl substituents, poly(ethylene glycol), binary stationary phase mixtures, and ionic liquid stationary phases. System constants at 20 °C intervals over the temperature range 60 - 140 °C are presented for 61 columns, and for 15 of these the temperature range is extended to > 200 °C and close to the maximum allowed operating temperature for the column. The Wayne State University 2025 (WSU-2025) compound descriptor database is used exclusively as the sole source for compound descriptors to unify the system constants with a verified descriptor database. A generic composition designation is employed for the classification of poly(dimethylsiloxane) columns, poly(dimethyldiphenylsiloxane) columns containing 5 % diphenylsiloxane monomer, poly(methylphenylsiloxane) columns, silarylene-siloxane copolymer columns engineered to emulate poly(dimethyldiphenylsiloxanes) containing 5 % diphenylsiloxane monomer, and poly(ethylene glycol) columns for which the within group variation of the system constants for columns from different sources are small compared to changes associated with the variation of monomer composition. The selectivity space is evaluated using principal component factor analysis and hierarchical cluster analysis and differences in column selectivity for nominally similar columns using system constant correlation plots with system constants over the temperature range 80 - 140 °C as variables. The influence of temperature on selectivity is evaluated using system maps created by the simultaneous plot of the column system constants as a continuous function of temperature.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...