Related Experiment Video
Updated: May 6, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Bench Testing Analysis of Perforation Management in the Setting of Bifurcation Coronary Intervention
Rayyan Hemetsberger1, Anass Maaroufi2, Kevin Hamzaraj1
1Department of Cardiology, Internal Medicine II, Medical University of Vienna, Vienna, Austria.
Background:
Management of coronary perforation in bifurcation lesions with covered stents remains challenging.
Aims:
We aimed to describe a proper practice and toolbox for "jailed-branch" management after covered stent deployment.
Methods:
Using a bench model, we tested various wires with a 120° angulated microcatheter for their ability to penetrate covered stents to access jailed side branches (SB). Next, four PCI techniques were assessed: Test #1 (main branch [MB] rupture simulation): MB covered stent, graft penetration, and kissing balloon inflation (KBI) (n = 7). Test #2: Test #1 completed with Culotte using a drug-eluting stent (DES) (n = 3). Test #3: Culotte with two covered stents simulating MB and SB rupture (n = 3). Test #4: Test #3 plus final DES in MB (n = 3).
Results:
High tip-load wires ( > 12 g) successfully penetrated covered stents within 14 s. All procedures were completed successfully. Test #1 showed lumen area reductions of -8% (MB) and -25% (SB), with graft overhang at the SB. Conversion to Culotte with DES (Test #2) improved SB lumen reduction to -8%. Test #3 showed reductions of -7% (MB) and -15% (SB), with graft overhang at MB, corrected in Test #4 by DES implantation, resulting in +9% lumen gain (MB) and improved SB lumen reduction (-11%).
Conclusion:
In this bifurcation perforation in-bench model, high tip-load wires effectively penetrated covered stents toward excluded branches after crossover covered stent implantation. Conversion to Culotte, using either a DES or a second covered stent, was feasible. Overhanging graft material following SB fenestration could be addressed by overstenting with a DES.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
14:35Post-Myocardial Infarction Heart Failure in Closed-chest Coronary Occlusion/Reperfusion Model in Göttingen Minipigs and Landrace Pigs
Published on: April 17, 2021
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Coronary Artery Disease I: Introduction
Coronary Artery Disease IV: Preventive Measures
Coronary Artery Disease V: Interprofessional Care
Acute Coronary Syndrome III: Diagnostic Studies