Related Experiment Video
Updated: Jan 8, 2026

Robotic D3 Partial Duodenal Resection with Primary Side-to-Side Anastomosis
Published on: December 15, 2023
Outpatient endoscopic submucosal dissection for non-ampullary duodenal lesions: a single-center experience at a U.S.
Abdulrahman Qatomah1,2, Daryl Ramai3, Aishah Qatomah4
1Gastroenterology, Hepatology, and Endoscopy, Brigham and Women's Hospital, Boston, MA, 02115, USA.
Introduction:
Endoscopic submucosal dissection (ESD) offers significant advantages, including the potential for curative resection of early-stage neoplasms. Despite this, the application of ESD for treating duodenal lesions remains sparse, particularly in the Western region. We aim to determine the feasibility of outpatient duodenal ESD from a tertiary referral center experience in the United States.
Methods:
Consecutive patients undergoing duodenal ESD from 2019 to 2024 at a tertiary referral center were included. The primary outcomes were the rate of en-bloc resection and curative resection. The secondary outcomes were the adverse event rate, including perforation or bleeding. Cohorts were compared using Chi-square, Fischer exact test, and logistic regression.
Results:
The study included 37 patients (57% females) with a mean age of 67 years (SD: 12). The mean diameter of the lesions was 39.1 mm (SD: 27.2), of which 54% (n = 20) were adenomatous lesions followed by 46% (n = 17) neuroendocrine lesions. All cases performed in an outpatient setting. Overall, 81% (n = 30) of lesions were removed by en-bloc resection, with a 67.6% (n = 25) R0 resection rate. Closure was performed in 68% (n = 25) of lesions. The adverse event rate was 5%, with two cases of delayed bleeding reported and no cases of delayed perforation. Mean resection time was 60 min (± 39 min). No significant difference was noted in en-bloc resection of adenomatous vs neuroendocrine tumors (69.6% vs 100%, P = 0.638) or R0 resection (69.6% vs 64%, P = 0.085), respectively.
Conclusion:
When performed by very experienced endoscopists, duodenal ESD can be performed effectively and safely for non-ampullary duodenal lesions, achieving high en-bloc resection rates with low adverse event rates. Defect closure may help mitigate delayed adverse events, supporting the feasibility of outpatient duodenal ESD.