Related Experiment Video
Updated: Jan 8, 2026

Measurement of Liver Stiffness Using Atomic Force Microscopy Coupled with Polarization Microscopy
Published on: July 20, 2022
Quantification of Liver Stiffness Using Magnetic Resonance Elastography in Comparison with Transient Elastography and
Preethi Sharon M1, Sameer Peer2, Anjali Raj3
1Junior Resident, Department of Radiodiagnosis, All India Institute of Medical Sciences, Bathinda, Punjab, India.
Background:
The global incidence of fatty liver (FL) [alcoholic and nonalcoholic FL disease (NAFLD)] is increasing. Imaging-based elastography techniques, being noninvasive, may eliminate the need for more invasive techniques for the diagnosis and staging of liver fibrosis in FL disease.
Objective:
Our study aims to address the gap in the current research by exploring the correlation between mean liver stiffness measurement (LSM) as obtained through magnetic resonance elastography (MRE) and transient elastography (TE), and two commonly used clinical scores, fibrosis-4 index (FIB-4) score and aspartate aminotransferase to platelet ratio index (APRI) score.
Materials And Methods:
In this hospital-based cross-sectional study, 62 patients diagnosed with FL on ultrasound were recruited. The patients were further subjected to MR liver elastography and TE, and LSM using both modalities was recorded. A history of diabetes mellitus and alcohol intake was taken. Moreover, noninvasive fibrosis scores such as FIB-4 and APRI were calculated using standard formulas.
Results:
The correlation analysis revealed a strong positive correlation between LSM values obtained from MRE and TE (r = 0.88) (Cohen's κ = 0.87), a moderate correlation between MRE and FIB-4 score (r = 0.44), and weak positive correlations involving MRE and APRI (r = 0.34), TE and FIB-4 score (r = 0.36), and TE and APRI (r = 0.29). Additionally, significantly higher fat fractions were quantified [median (IQR)] in grade III FL [23.6 (15.9-29.5)] as compared to grades I [8.45 (2.25-13.9)] and grade II [13.1 (8.4-19.7)].
Conclusion:
MRE shows a strong positive correlation with TE for LSM and stage of fibrosis. Our findings suggest that MRE could be a valuable tool in the diagnostic armamentarium of FLD.
More Related Videos
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025