Related Experiment Video
Updated: Jan 8, 2026

Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
Published on: July 25, 2025
High rate pervaporation and disinfection efficacy of hypochlorous acid in vacuum-driven membrane process
Ayaka Sakurai1, Chisato Shimada1, Satoshi Fukuzaki1
1Graduate School of Bioresources, Mie University.
Abstract:
This study investigated the pervaporation of hypochlorous acid (HOCl) using a vacuum-driven process with a separation module containing 6,000 silicone rubber (SR) hollow fibers. Gaseous hypochlorous acid (HOCl(g)) discharged from the membrane module was accumulated in a 1 m3 chamber. Weakly acidic (pH 5.0) hypochlorite solutions with free available chlorine (FAC) concentrations of 100-1,000 mg/L were fed through the lumen of the SR hollow fibers. Both the HOCl permeation rate and the steady-state HOCl(g) concentration increased with the feed FAC concentration. When a 1,000 mg/L hypochlorite solution was used, the HOCl(g) concentration in the chamber reached 5,500 ppb within 40 min. This accumulated HOCl(g), when applied to microorganisms on wet agar plates at a concentration of approximately 320 ppb, achieved a >3-log reduction in viable bacterial cells within 10 min and fungal spores within 20 min. These results demonstrate that high-rate pervaporation of HOCl can be achieved using an SR hollow fiber membrane in a vacuum-driven process, and the resulting HOCl(g) is effective for rapid disinfection.
More Related Videos
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
07:45Electrophoretic Crystallization of Ultrathin High-performance Metal-organic Framework Membranes
Published on: August 16, 2018
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
High-Performance Liquid Chromatography: Elution Process
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Chemical Agents for Microbial Control