Related Experiment Video
Updated: Jul 16, 2026

An in vivo Rodent Model of Contraction-induced Injury and Non-invasive Monitoring of Recovery
Published on: May 11, 2011
Sensitivity of Structural and Mechanical Markers of Muscle and Tendon Damage Responses After Eccentric Plantar Flexor
Ecaterina Vasenina1, David H Fukuda2, Jack J Livingston2
1Human Performance Lab, Department of Health Sciences and Human Performance, The University of Tampa, Tampa, Florida.
Abstract:
Vasenina, E, Fukuda, DH, Livingston, JJ, Antonio, BB, Herda, AA, Mangum, LC, and Stout, JR. Sensitivity of structural and mechanical markers of muscle and tendon damage responses following eccentric plantar flexor exercise. J Strength Cond Res 40(3): 293-303, 2026-This study aimed to investigate the acute structural and functional responses of the calf musculature and Achilles tendon following an eccentric exercise-induced muscle damage (EIMD) protocol and to evaluate the sensitivity of diverse assessment tools. Twenty young, recreationally active men performed a unilateral EIMD protocol consisting of 4 × 50 heel drops plus a final set to failure wearing a weighted vest equal to 40% of body mass, while the contralateral leg served as a control. Assessments included gastrocnemius and Achilles tendon thickness and length (ultrasound), calf circumference, pressure pain threshold, isometric strength, myotonography, and global/local pain ratings. Measurements were collected at baseline and 0, 24, 48, and 72 h postexercise. Significant visit × leg interactions ( p < 0.05) were observed across most markers. Gastrocnemius thickness increased by 22.4% immediately after and remained 12.9% elevated at 72 h. Achilles tendon thickness decreased by 21.7% postexercise, while tendon length increased by 12%. Isometric strength declined 15-25% at 24-48 h. Calf creep and relaxation times also decreased >15% across time points. Numerical Pain Rating Scale peaked at 48 h (mean increase of +37 points). Pressure pain threshold was significantly lower in the intervention leg at all time points ( p < 0.01). Eccentric plantar flexor exercise induced significant changes in muscle-tendon structure and function. Gastrocnemius thickness, tendon morphology, strength, myotonographic properties, and pain ratings were among the most sensitive indicators. These findings highlight the value of using a multimodal battery, including ultrasound, myotonography, strength testing, and pain ratings, to comprehensively monitor recovery after eccentric exercise.
Related Concept Videos
Cell-matrix's Response to Mechanical Forces
Anchoring junctions mechanically attach a cell to the...
Phases of Wound Repair
Formation of Blood Clot
In case of deep injuries, trauma to blood vessels results in blood loss. In the meantime, phospholipids released from the ruptured endothelial cellular membrane are converted into arachidonic...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Overview of Muscle Tissues
Elasticity
Elasticity is the ability of muscles to stretch and return to their original shape. This property is partly due to elastic fibers — macromolecules that run through the muscles. These fibers are firm and resilient,...
Somatic Spinal Reflexes
One of the most well-known somatic spinal reflexes is the stretch reflex, which is activated by the sudden stretching of a muscle. This reflex involves the activation of specialized sensory receptors called muscle spindles, which are located in the muscle tissue and detect changes in the length and speed of muscle contractions. When a muscle is suddenly...

