Related Experiment Video
Updated: Jan 8, 2026

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Carbon footprint comparison of video intubation tools: Disposable laryngoscopes, reusable laryngoscopes, and stylets
Danyang Pan1, Yating Yang1, Sirui Chen2
1Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
Purpose:
As healthcare systems grapple with their 5% global carbon footprint contribution, sustainable medical device selection emerges as a critical decarbonization lever. This life cycle assessment (LCA) quantifies environmental disparities among three prevalent video intubation tools-Disposable video laryngoscopes (VLs), reusable VLs, and video Stylets-to guide evidence-based procurement.
Methods:
Using International Organization for Standardization (ISO)14040 compliant life cycle assessment (LCA) methodology-the international standard defining LCA principles and framework-we quantified cradle-to-grave emissions for three video intubation devices manufactured by Zhejiang UE Medical Corp. The functional unit (one tracheal intubation) incorporated material extraction, manufacturing, low-temperature LTPS/ HLD, transportation, and disposal. SimaPro 9.4.0 with Ecoinvent 3.8 database calculated CO₂ equivalents (kg CO₂e), validated through sensitivity analyses of sterilization loading (10-80 devices/cycle) and regional grids.
Results:
The HLD-disinfected video stylet demonstrated superior environmental performance, emitting 98.24 kg CO₂e per 500 procedures-45.8% and 42.0% lower than reusable VLs (181.45 kg CO₂e) and disposable VLs (169.47 kg CO₂e), respectively. Sensitivity analyses identified sterilization loading as the dominant variable: half-load (50% chamber utilization) reduced emissions by 89-91% versus single-device processing, with full-load optimization yielding incremental 11-14% reductions. Process and regional variability further revealed that HLD decreased emissions by 19-24% compared to LTPS, while grid carbon intensity caused 24-33% variability (India vs. EU). Scenario comparisons confirmed the video stylet's environmental dominance across sterilization methods-even with LTPS (349.99 kg CO₂e/500 uses), it maintained a 45% reduction over reusable VL baselines, whereas HLD-treated video stylets (94.32 kg CO₂e) showed 6.7-fold lower emissions than disposable VLs and 59% below HLD-reprocessed reusable VLs.
Conclusions:
HLD-reprocessed video stylets are the environmentally optimal choice for high-volume, low-infection-risk settings. For low-throughput or high-risk scenarios, providers should balance environmental impacts with clinical requirements through frequency and resource assessment.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required