Related Experiment Video
Updated: Jan 8, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Exploring spatiotemporal information in a Cherenkov and scintillation photon counting BGO TOF-PET semi-monolithic
Seungeun Lee1, Ryan Heller1, Woon-Seng Choong1
1Applied Nuclear Physics Program, Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America.
Abstract:
Objective. Cherenkov signatures from a bismuth germanate (BGO) crystal open the possibility of establishing BGO as a promising material for time-of-flight positron emission tomography (TOF-PET) detectors, particularly if the first Cherenkov photons can be uniquely timestamped. To maximize the utility of Cherenkov signatures, we employed an optical photon counting detector concept based on a thick, semi-monolithic BGO crystal coupled to a silicon photomultiplier (SiPM) array that provides digital photon timestamps from each SiPM channel. We characterized a prototype detector to demonstrate this concept and explored the use of rich spatiotemporal information of photon transport kinetics.Approach. The detector was built using a 42.68 × 2 × 20 mm3BGO crystal and a 16 × 1 array of 2 × 2 mm3SiPMs with a 2.68 mm pitch. A 16-channel low-noise high-frequency signal processing chain with fast comparators generated digital photon signals, which were recorded using waveform digitizers. Three-dimensional (3D) position calibration and first photon delay distribution (FPDD) construction provided the basis for data-driven methods to improve time resolution and estimate the probability of Cherenkov detection for each event.Main results. With a sufficient number of SiPM channels and 1.8 ns signal shaping, approximately 77% of events were uniquely timestamped with the first photon. FPDD clearly captured photon arrival properties, parameterized with the Cherenkov and scintillation contributions. A coincidence time resolution with a reference detector of 172 ps full width at half maximum was achieved by FPDD-based correction of 3D position dependence. Parameters investigated for Cherenkov detection probability estimation showed consistent correlation with time resolution.Significance. The results demonstrated the feasibility of a photon counting BGO detector for TOF-PET with both promising timing and positioning performance. The abundance of photon information provides a strong basis for further performance gains through data-driven Cherenkov identification and advanced event-by-event corrections.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
High-Performance Liquid Chromatography: Types of Detectors