Related Experiment Video
Updated: Jan 8, 2026

Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
Dual Comb Spectrometer for the Determination of Stable Isotopic Ratios of Atmospheric CO2 with Sub-Permille Precision
Jens Goldschmidt1, Nicolas Brugger1, Leonard Nitzsche1
1Laboratory for Gassensors, Department of Microsystems Engineering-IMTEK, University of Freiburg, Georges-Köhler-Allee 102, 79110 Freiburg, Germany.
Abstract:
We present a mid-infrared dual comb spectrometer for the precise determination of the isotopic ratio of the stable CO2 isotoplogues 12C16O2 and 13C16O2 under atmospheric pressure. The spectrometer is based on electro-optic intensity modulation at 1550 nm wavelength and subsequent wavelength flexible conversion to the mid-infrared. Here, the fundamental absorptions of CO2 in the ν3 band around 4.3 μm wavelength (2300 cm-1) were accessed to achieve the needed sensitivity to investigate the isotopic composition at atmospheric concentrations. The high spectral resolution of 0.004 cm-1 and spectral coverage of 8 cm-1 enable the measurements of the three most abundant CO2 isotopologues 12C16O2, 13C16O2 and 16O12C18O at ambient pressure. The high average signal-to-noise ratio per comb mode of 51 dB and a noise equivalent absorption coefficient of 5.4(9)·10-6 cm-1 Hz-1/2 ensures high precision. After an integration time of 172 s a precision on the stable isotopic ratio (δ13C) of <0.1‰ is achieved according to Allan deviation analysis. A linearity analysis on the measured concentrations of the single isotopologues results in coefficients of determination (R2) of 0.999 for CO2 concentrations ranging from 300 to 450 ppm, whereas for the measurement of δ13C-values ranging from -36.5‰ and -5.4‰ a coefficient of determination of 0.998 was achieved. This linear behavior and the high precision on the measurements demonstrate the great potential of the presented dual comb spectrometer for atmospheric research. Especially, where measurements under low pressure must be avoided, the here presented system is a promising alternative to established quantum cascade laser-based systems.
More Related Videos
11:19Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Emission Spectroscopy: Instrumentation
Tandem Mass Spectrometry