Related Experiment Video
Updated: Jan 8, 2026

06:21
Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
7.4K
An innovative determination approach for the support strength of stope roof: a case study
Kunmeng Li1,2, Jiaqi Zhang3,4, Yuanhui Li3,4
1State Key Laboratory of Intelligent Deep Metal Mining and Equipment, Northeastern University, Shenyang, 110819, China. likunmeng@mail.neu.edu.cn.
Scientific Reports
|December 16, 2025
Abstract
No abstract available in PubMed .
Related Concept Videos
Design Consideration
508
Designing a structure involves a series of considerations, primarily the material's ultimate strength, calculated through tests that measure changes under increased force until the material reaches its breaking point or limit. The ultimate load, where the material breaks, is divided by its original cross-sectional area, resulting in the ultimate normal stress or strength. The ultimate shearing stress is another significant factor taken into account.
The factor of safety is another key...
The factor of safety is another key...
508
Method of Sections: Problem Solving II
1.6K
Consider an arbitrary truss structure composed of diagonal, vertical, and horizontal members fixed to the wall. To calculate the force acting on members CB, GB, and GH, method of sections can be used. The loads and lengths of the horizontal and vertical members are known parameters, as shown in the figure.
1.6K
Method of Sections: Problem Solving I
1.0K
Consider a symmetrical roof truss structure, composed of vertical, diagonal, and horizontal members. The length of each horizontal member is 4 m. The lengths of the vertical members FB and HD are 4 m, while the length of member GC is 6 m. The loads acting at joints F, G, and H are 2 kN, while those at joints A and E are 1 kN.
1.0K
Internal Loadings in Structural Members: Problem Solving
1.7K
When designing or analyzing a structural member, it is important to consider the internal loadings developed within the member. These internal loadings include normal force, shear force, and bending moment. Engineers can ensure that the structural member can support the applied external forces by calculating these internal loadings.
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
1.7K
Statically Indeterminate Problem Solving
666
Statically indeterminate problems are those where statics alone can not determine the internal forces or reactions. Consider a structure comprising two cylindrical rods made of steel and brass. These rods are joined at point B and restrained by rigid supports at points A and C. Now, the reactions at points A and C and the deflection at point B are to be determined. This rod structure is classified as statically indeterminate as the structure has more supports than are necessary for maintaining...
666
Posttensioned Masonry Walls
436
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
436