Related Experiment Video
Updated: Jan 8, 2026

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
A Simple Online Internal Standard Calibration Strategy for Single-Particle Inductively Coupled Plasma Mass
Xiangwei Tian1,2,3,4, Ying Wang1, Peijie Yang2,3
1School of Environment, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou 310024, China.
Abstract:
Single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) is a powerful tool for resolving particle heterogeneity. However, in real environmental and biological samples, matrix effects pose significant challenges to accurate mass/size determination. Herein, we first systematically investigated the specific matrix effects on each stage of SP-ICP-MS analysis. Results showed that the sizes of Ag nanoparticles in the typical matrices were underestimated by nearly 10 nm due to 30-50% signal attenuation. To address this issue, we developed an online internal standard calibration strategy based on multielement detection and nonanalyte elements as internal standards. The theory of a novel calibration approach involving the use of nonanalyte elements as internal standards for signal response calibration was proposed and experimentally validated. The multielement detection mode was employed to measure the analyte (Ag) and internal standard elements (Pd and Au) within a single analytical run, enabling simultaneous correction of matrix-induced variations in signal response and nebulization efficiency. Under optimized time-resolution conditions (dwell time of 5 ms), the measured sizes of the particles in both simulated and real matrices showed good agreement with the true values. Overall, the proposed method provides a simple, reliable, and flexible solution for extending the applicability of SP-ICP-MS to the analysis of complex environmental and biological samples.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Mass Analyzers: Common Types

