Related Experiment Video
Updated: Jan 8, 2026

Optical Screening of Novel Bacteria-specific Probes on Ex Vivo Human Lung Tissue by Confocal Laser Endomicroscopy
Published on: November 29, 2017
Requirements for Physico-Technical Quality Assurance in the Framework of Early Detection of Lung Cancer
Rainer Eßeling1, Mathis Konrad2,3, Hannah Prokesch3
1Clinic for Radiology, University Hospital Münster, Münster, Germany.
Abstract:
According to the text of the Lung Cancer Screening Ordinance on the permissibility of using low-dose computed tomography to screen smokers (LuKrFrühErkV, §7 Quality Assurance, 1), the "radiation protection officer must establish and operate a comprehensive quality assurance system. This must take account of organizational, medical, and technical aspects, in particular [...] 2. the diagnostic image quality of the computed tomography scan, 3. the physical-technical parameters for the acquisition of the computed tomography scan [...]". The German Radiological Society (DRG) considers itself responsible for making recommendations regarding the implementation of such a quality assurance system, in order to provide users with legal certainty and ensure patient safety. The DRG's Physics and Technology Working Group has thus identified the main issues regarding quality assurance for technology, outlined the related challenges, and proposed potential areas for future investigation and resolution (see sections I-V). Existing quality assurance measures for technology must be checked for their suitability with regard to a low-dose screening program and adapted, if necessary. Complex additional constancy tests and the use of special (anthropomorphic) phantoms are not currently considered necessary. The tasks of manufacturers and medical physicists were refined further, and it was recommended that reference centers should be established as soon as possible. · Constancy testing methods for CT are largely sufficient for lung cancer screening.. · Daily air calibration is recommended to ensure consistent image quality.. · Anthropomorphic phantoms are not currently required for quality assurance.. · Manufacturers must provide protocols that meet LuKrFrühErkV requirements.. Eßeling R, Konrad M, Prokesch H et al. Requirements for Physico-Technical Quality Assurance in the Framework of Early Detection of Lung Cancer. Rofo 2026; DOI 10.1055/a-2597-0689.
Related Concept Videos
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

