The relationship between the Ewald sphere and exit wave explored using focal series electron micrographs
1National Cryo-EM Program, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Leidos Biomedical Research Inc., Frederick, MD 21701, USA.
Iucrj
|December 19, 2025
Summary
Cryo-electron microscopy (cryoEM) reconstructions require accounting for Ewald spheres to improve resolution. Applying both halves of the contrast transfer function (CTF) to particle images correctly incorporates Ewald spheres for better reconstructions.
Area of Science:
- Structural Biology
- Microscopy Techniques
- Computational Imaging
Background:
- CryoEM reconstructions aim for high resolution, often limited by the projection approximation.
- Image formation in cryoEM involves scattering and lens effects modeled by conjugate Ewald spheres.
- Focal series data capture Ewald sphere wavefronts, visualized in 3D Fourier transforms.
Purpose of the Study:
- To investigate the nature of Ewald spheres in cryoEM image formation.
- To develop and validate methods for correcting the contrast transfer function (CTF) across focal series.
- To establish the optimal approach for incorporating Ewald sphere information into cryoEM reconstructions.
Main Methods:
- Acquisition of focal series for graphene oxide and platinum-iridium specimens.
- Development of an algorithm for fitting and correcting the CTF of entire focal series.
- Application of partial CTF correction to individual micrographs and 2D reconstructions.
- Iterative refinement of reconstructions against original focal series amplitudes.
Main Results:
- Partial CTF correction flattens one Ewald sphere while increasing the curvature of the other, optimizing the exit wave representation.
- 2D reconstruction by summing partially corrected transforms recovers missing information and enhances signal-to-noise ratio.
- Iterative refinement can recover the second Ewald sphere in overlapping frequency ranges but may introduce artifacts.
Conclusions:
- The correct method for Ewald sphere accounting in cryoEM involves applying both CTF halves to particle images.
- The results from each CTF half should be integrated into their respective Ewald spheres within the cryoEM reconstruction process.
- This approach enhances resolution and accuracy in cryoEM structural determination.
Related Concept Videos
The de Broglie Wavelength
32.9K
In the macroscopic world, objects that are large enough to be seen by the naked eye follow the rules of classical physics. A billiard ball moving on a table will behave like a particle; it will continue traveling in a straight line unless it collides with another ball, or it is acted on by some other force, such as friction. The ball has a well-defined position and velocity or well-defined momentum, p = mv, which is defined by mass m and velocity v at any given moment. This is the typical...
32.9K
Overview of Electron Microscopy
12.9K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
12.9K
Transmission Electron Microscopy
6.8K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
6.8K
Eccentricity of an Ellipse
226
An ellipse is a fundamental conic section defined by the constant sum of distances from any point on its curve to two fixed points, known as the foci. This geometric property can be physically demonstrated using a pencil, string, and two pins. By anchoring the string at both ends and maintaining it taut with a pencil, one can trace the outline of an ellipse.The shape and extent of the ellipse are determined by its eccentricity, e, defined as the ratio of the distance between the center and a...
226
Standing Electromagnetic Waves
2.2K
Electromagnetic waves can be reflected; the surface of a conductor or a dielectric can act as a reflector. As electric and magnetic fields obey the superposition principle, so do electromagnetic waves. The superposition of an incident wave and a reflected electromagnetic wave produces a standing wave analogous to the standing waves created on a stretched string.
Suppose a sheet of a perfect conductor is placed in the yz-plane, and a linearly polarized electromagnetic wave traveling in the...
Suppose a sheet of a perfect conductor is placed in the yz-plane, and a linearly polarized electromagnetic wave traveling in the...
2.2K
Scanning Electron Microscopy
5.3K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
5.3K