Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Brazil's First High-Risk Percutaneous Coronary Intervention with Hemodynamic Support from a Percutaneous Pulsatile
André M Nicolau1, Pedro H M C de Melo1, Lucas Aguiar Alencar de Oliveira1
1Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP - Brasil.
None:
Percutaneous coronary intervention (PCI) is the most widely used coronary revascularization method worldwide, even in cases of high anatomical complexity. However, this increasing complexity has increased the risks associated with the procedure. Mechanical circulatory assist devices (MCADs), such as the iVAC 2L, have been used for hemodynamic support in high-risk PCIs. We describe the first case in Brazil of PCI performed with the support of the iVAC 2L, a pulsatile MCAD. The patient, an 81-year-old man, had functional class III angina and severe lesions in the left main coronary artery (LMCA), left anterior descending artery (LAD), and circumflex artery (CX), associated with extensive calcification. The procedure was performed with the support of the iVAC 2L, and PCI was performed with stenting of the LMCA, LAD, and CX. The entire procedure was performed without the need for vasoactive drugs, and the device was removed without vascular complications. High-risk PCI has become increasingly common, often requiring ventricular mechanical support. The iVAC 2L offers advantages such as pulsatile flow and ease of implantation, making it an alternative to the intra-aortic balloon pump and Impella. This report highlights the potential use of the iVAC 2L in Brazil, expanding therapeutic options for high-risk patients.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peripheral Artery Disease I: Introduction
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation