Comparative evaluation of CortexID and VIZCalc software in brain amyloid PET: a retrospective study of 116 cases
Manduukhai Badarchin1, Yoichi Otomi2, Takayoshi Shinya3
1Department of Radiology, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-cho, Tokushima, 770-8503, Japan.
Background:
Quantitative analysis of amyloid positron emission tomography (PET) is increasingly applied in clinical and research settings; however, its consistency across software platforms remains uncertain. This study aimed to compare standardized uptake value ratio (SUVr) measurements obtained from CortexID Suite and VIZCalc, to evaluate their concordance with expert visual assessment, and to assess the concordance of Centiloid values derived from VIZCalc with the visual reference.
Methods:
We retrospectively analyzed 116 patients who underwent 18F-flutemetamol PET at a single institution. SUVr values were calculated using both CortexID Suite and VIZCalc, while Centiloid values were derived from VIZCalc only. Visual assessments were performed by two nuclear medicine physicians. Correlations among indices were examined using Pearson's correlation. Agreement between SUVr values was assessed with Bland-Altman analysis. Agreement with the non-independent visual reference was evaluated using receiver operating characteristic (ROC) analysis, and areas under the curves (AUCs) were compared with DeLong's test.
Results:
SUVr values from CortexID and VIZCalc were strongly correlated (r = 0.986, p < 0.001), with a small mean difference of + 0.0397. Both platforms showed high concordance with the non-blinded visual assessment (AUC: 0.991 for CortexID; 0.989 for VIZCalc). Centiloid values also showed high agreement with the visual reference (AUC: 0.994) and were strongly correlated with SUVr values (r = 0.975 for CortexID; r = 0.965 for VIZCalc, p < 0.001). No significant difference was observed between platforms (p = 0.84).
Conclusions:
CortexID Suite and VIZCalc demonstrated high concordance with the non-blinded visual assessment and showed consistent quantitative trends. Both platforms can be reliably applied for amyloid burden quantification, provided that software-specific characteristics are appropriately considered.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography