Related Experiment Video
Updated: Jan 8, 2026

Antimicrobial Synergy Testing by the Inkjet Printer-assisted Automated Checkerboard Array and the Manual Time-kill Method
Published on: April 18, 2019
Multicentric evaluation of the MTS™ Synergy Application System for reliable antibiotic synergy testing in clinical
Edoardo Carretto1, Stefano Andreoni2, Richard Ashbacher3
1S.O.C. Microbiologia - Arcispedale Santa Maria Nuova, IRCCS-AUSL Reggio Emilia, Italy; U.O.C. Microbiologia e Virologia - Azienda Socio Sanitaria Territoriale "Papa Giovanni XXIII", Bergamo, Italy.
Objectives:
The rise of antimicrobial resistance poses a major challenge for both clinicians and clinical microbiologists. There is an increasing need for user-friendly and reliable methods to assess the activity of antibiotics against multidrug-resistant (MDR) strains. Although synergy testing provides valuable insights, conventional methods such as checkerboard assays and time-kill studies are labour-intensive, technically demanding, and difficult to standardize. This study evaluated the MTS™ SAS (MIC Test Strip - Synergy Application System, Liofilchem, Italy), a commercial gradient diffusion assay developed for antibiotic synergy testing.
Methods:
The performance of MTS™ SAS was evaluated in comparison with the checkerboard microdilution method, used as the reference standard. Nine antibiotic combinations were tested against ten different bacterial strains across 11 Italian hospitals. Inter-laboratory reproducibility and agreement with the reference method were analysed.
Results:
The concordance between MIC test strips and the broth microdilution (BMD) method was 98.4%, with 1.6% showing discordant results - all within a 3-dilution range. Among 996 synergy determinations, MTS™ SAS demonstrated high reproducibility across all centers (96.7%), while only 3.3% of tests showed discordant synergy classifications (e.g., synergy vs. indifference). Comparison with the checkerboard method demonstrated an overall concordance of 96.2%, despite the absence of specific operator training at each site.
Conclusion:
These findings support MTS™ SAS as a practical and reliable alternative to conventional synergy testing methods, particularly suitable for routine clinical settings and laboratories lacking advanced microbiological expertise.
More Related Videos
12:39Antimicrobial Susceptibility Testing of Mycobacterium Tuberculosis Complex for First and Second Line Drugs by Broth Dilution in a Microtiter Plate Format
Published on: June 24, 2011
09:09High Throughput, Real-time, Dual-readout Testing of Intracellular Antimicrobial Activity and Eukaryotic Cell Cytotoxicity
Published on: November 16, 2016
Related Concept Videos
Urine Studies II: Urine Culture and Sensitivity Test
Combined Effects of Drugs: Synergism
Such synergistic combinations...