Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
A novel method for acoustic modeling of cranial bone based on the porosity index
Dechen Kong1, Tao Zhang2,3,4, Guozheng Hou1
1Zhejiang Cancer Hospital, Hangzhou, 310022, Zhejiang, China.
Abstract:
Transcranial ultrasound stimulation (TUS) has emerged as a clinically validated neuromodulation technique. Particularly, phased array ultrasound can be applied in TUS to focus on the cortex or deep brain non-invasively, such as the ventral intermediate thalamic nucleus (VIM) and Precuneus (PCu) region for the treatment of essential tremor (ET) and Alzheimer Disease (AD). Current TUS treatment planning relies on computed tomography (CT)-derived skull porosity measurements, which involve patient radiation exposure and potential registration errors. This study proposes a Porosity Index (PI)-based method, derived from Ultrashort Echo Time (UTE) Magnetic Resonance (MR) images, for establishing skull acoustic models as a viable alternative, aiming to eliminate these limitations. Acoustic simulations using the K-Wave open-source platform were performed to validate the PI method's accuracy in predicting skull porosity and simulating focal distributions compared to CT. Focal spot characteristics were quantified using five metrics: peak intensity, target intensity, focal positioning error, Dice similarity coefficient, and Pearson correlation coefficient between CT- and PI-based simulation results. Statistical differences between these metrics were assessed using Tukey's multiple comparisons test. Quantitative comparisons against the gold-standard CT approach demonstrated comparable performance in peak focal intensity (deviation < 5%) and spatial pressure distribution patterns (Dice coefficient > 0.82). No significant differences (p > 0.05) were observed for any of the evaluated metrics. Our findings demonstrate that both the sound pressure distribution and prediction of the porosity are comparable with those from the reference CT. Using the PI to replace the traditional CT porosity has high feasibility and can achieve the purpose of reducing unnecessary radiation exposure and registration error for patients.
More Related Videos
07:52Author Spotlight: Advancing Human Brain Modulation – Optimized Protocols for Transcranial Ultrasound Stimulation Experiments
Published on: June 28, 2024
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Related Concept Videos
Cranial Bones: Lateral View
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
Cranial Bones: Superior and Posterior View
The frontal bone is the single bone that forms the forehead. At its anterior midline, between the eyebrows, there is a slight depression called the glabella. The frontal bone also forms the supraorbital margin of the orbit. Near the middle of this margin is the supraorbital foramen, the opening that provides passage for a sensory nerve to the forehead. The frontal bone is thickened just above each supraorbital margin,...