Related Experiment Video
Updated: Jan 8, 2026

Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
Performance evaluation of a ring-worn pulse oximeter for the identification and monitoring of obstructive sleep apnea
Laura K Gell1, Ketan Mehta1, Neda Esmaeili2
1Apnimed Inc., Cambridge, MA, United States.
Introduction:
Obstructive sleep apnea (OSA) is a highly prevalent chronic disorder that is challenging to monitor clinically. While single-night laboratory-based polysomnography (PSG) is the current gold standard for OSA assessment, its utility is limited by cost and inaccessibility. Overnight pulse oximetry is a feasible approach for simplified at-home monitoring of OSA. In this study, we evaluate the performance of a modified finger-worn pulse oximetry device ("Ring") for OSA assessment.
Methods:
In all, 25 patients with OSA [age: 55.5 ± 7.7 years (mean ± SD), body mass index (BMI): 31.8 ± 5.1 kg/m2, 14M:11F, and Fitzpatrick scale score I-II: 15, III-IV: 6, and V-VI: 4] completed up to four in-laboratory PSG studies with simultaneous Ring oximetry measurements (90 studies in total). Correlation and agreement analyses compared Ring-derived measures of the oxygen desaturation index (ODI4RING, desaturations ≥4%) against PSG measures (ODI4PSG and AHI4PSG). Likewise, Ring-derived hypoxic burden (HBRING) was compared against its PSG counterpart (HBPSG). Receiver operator characteristic (ROC) curve analysis quantified the ability of ODI4RING to identify moderate-to-severe OSA (AHI4PSG > 15 events/h).
Results:
Median [interquartile range (IQR)] of AHI4PSG was 18.0 [9.6, 31.7] events/h. ODI4RING was positively correlated with ODI4PSG (Pearson r = 0.87, root mean square error [RMSE] = 6.6 events/h, intraclass correlation [ICC] = 0.85) and AHI4PSG (r = 0.85, RMSE = 7.1 events/h, ICC = 0.84). The bias (mean difference) and limits of agreement (1.96 SD) between ODI4PSG and ODI4RING were 2.9 and 14.2 events/h, while for AHI4PSG and ODI4RING, the bias and limits of agreement were 1.4 and 16.3 events/h, respectively. HBRING was positively correlated with HBPSG (r = 0.75, RMSE = 24.6% min/h, ICC = 0.73), with a mean difference of 3.7% min/h and limits of agreement of 60.6% min/h. The receiver operator characteristic curve analysis of ODI4RING to identify moderate-to-severe OSA produced an area under the curve of 0.92 (ODI4PSG > 15 events/h, "excellent") and 0.84 (AHI4PSG > 15 events/h, "excellent").
Conclusion:
Our results show that a low-cost, convenient, and simple-to-use finger-worn pulse oximeter is a reliable tool for continuous monitoring of OSA severity and therapy responses. It also offers excellent discriminative value for screening moderate-to-severe OSA in this population.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Sleep Apnea
The condition is more prevalent among...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse rhythm