Carboxylated Polystyrene Particles for Plastic Standards in Laser Ablation ICP-MS Trace Elements Analysis: Analytical
Maud Gautier1, Sandra Mounicou1, Javier Jiménez-Lamana1
1Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM, 64053 Pau, France.
None:
Reliable quantification of trace metals in polymers by direct solid-state analysis remains limited by the lack of suitable reference materials. In this study, we introduce a novel method for producing standardized plastic samples specifically designed for the calibration and analysis of trace metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Carboxylated polystyrene (PS) nanoparticles, capable of adsorbing metal ions from solution, were synthesized and evaluated. The trace metal adsorption capabilities of these PS nanoparticles were assessed with adsorption isotherms fit well with the Freundlich model. The study focused cobalt (Co2+), copper (Cu2+), and lead (Pb2+) The adsorption constants were found to be 0.15 for Co2+, 0.48 for Cu2+, and 3.63 for Pb2+. The metal-sorbed PS nanoparticles were then processed into disc-shaped plastics via hot-press molding, and LA-ICP-MS analysis confirmed the homogeneous metal distribution both at the surface and in depth, with relative standard deviations (RSD) of less than 5% for all metals analyzed. Calibration curves for Pb2+ (1220-4400 mg kg-1), Cu2+ (210-600 mg kg-1), and Co2+ (67-220 mg kg-1) showed strong linear relationships, with R 2 values of 0.96 for Pb2+, 0.95 for Cu2+, and 0.94 for Co2+. The methodology limits of detection (LOD) were determined to be 113 mg kg-1 for Pb2+, 93 mg kg-1 for Cu2+, and 23 mg kg-1 for Co2+. The developed standards enabled the calibration of analytical instruments and thus improve the reliability of assessments concerning the contamination of environments with metal-laden microplastics.
More Related Videos
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
