Accurate Proton Stopping Power Images Reconstructed using Joint Statistical Dual Energy CT: Experimental Verification
Maria Medrano1, Ruirui Liu2, Tyler Webb3
1Washington University in St.Louis, Department of Electrical and Systems Engineering.
Abstract:
Proton radiotherapy has the potential to provide clinically effective treatment and highly conformal dose delivery when the rapid dose falloff at the end of its proton-beam range is correctly aligned to the distal margin of the clinical target volume. However, in current clinical practice an additional 2-3.5% safety margin must be added to the proton range to account for uncertainties in the estimation of proton-beam range when using stopping-power ratios (SPRs) derived from single-energy CT scans. Several approaches have been proposed to estimate stopping power by using dual-energy CT (DECT) and have been shown through theoretical analysis to outperform single-energy CT (SECT) under the presence of tissue composition and density variations. Our lab previously proposed a joint statistical image reconstruction (JSIR) method built on a basis-vector model (BVM) tissue parameterization for SPR estimation, which was shown to perform comparatively better than other DECT image- and sinogram-domain decomposition approaches on simulated as well as experimental data. This comparison, however, assumed theoretical SPR values calculated from the samples' known compositions and densities as ground truth and used the mean excitation energy and effective electron density from ICRU reports along with a simplified version of the Bethe-Bloch equation to determine SPR reference values. Furthermore, CT scans were acquired with an assumed ideal point source at a narrow beam collimation; thus, the signal formation assumed by our JSIR process neglected scatter and off-focal radiation. In this paper, we verify the accuracy of our method by comparing the SPR values derived from JSIR-BVM to direct measurements of relative SPR, as well as present a preliminary study on the impact of fan-beam scatter radiation on JSIR-BVM SPR prediction accuracy.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...