Related Experiment Video
Updated: Jun 6, 2026

16:40
T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
Published on: July 31, 2010
25.2K
Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations
Jung Yun Lee1, Viraj D Gandhi1, Christopher Harrilal1
1Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
Analytical Chemistry
|December 23, 2025
Summary
Multipass Structures for Lossless Ion Manipulations (SLIM) enhanced gas-phase protein separation, accurately determining charge-state-dependent structures. This advancement enables new native ion mobility spectrometry applications.
Area of Science:
- Analytical Chemistry
- Biophysical Chemistry
- Separation Science
Background:
- Structures for Lossless Ion Manipulations (SLIM) offer high-resolution ion separations in the gas phase.
- Previous SLIM applications have focused on various molecular classes, but protein analysis requires further development.
Purpose of the Study:
- To investigate multipass SLIM for separating gas-phase proteins in a near-native state.
- To analyze charge-state-dependent arrival time distributions and conformational changes in proteins.
- To validate SLIM-derived collision cross-section (CCS) values against drift tube ion mobility spectrometry (DTIMS).
Main Methods:
- Utilized multipass SLIM separations for carbonic anhydrase (CA), alcohol dehydrogenase (ADH), and apo-transferrin.
- Obtained experimental CCS values using calibration curves with Agilent Tune Mix ions.
- Deconvoluted multipass arrival time distributions (ATDs) into single-pass values for CCS determination.
- Compared SLIM-derived CCS values with DTIMS measurements.
Main Results:
- Baseline separation of CA charge states (z=9+ to 11+) achieved with 8-m single-pass SLIM.
- Improved mobility peak resolution for ADH (z=23+ to 25+) with extended path lengths up to 24-m.
- Observed transition from unimodal to multimodal CCS distributions for apo-transferrin (z=16+ to 18+).
- Demonstrated selective isolation of specific charge states (e.g., apo-transferrin z=17+) using 40-m multipass separations.
- SLIM separations showed minimal impact on protein structure and CCS values.
Conclusions:
- Multipass SLIM effectively separates gas-phase proteins in a near-native state, resolving charge-state-dependent structures.
- The technique provides accurate CCS values comparable to DTIMS.
- SLIM's capability for mobility-selective isolation opens avenues for native ion mobility applications and further SLIM-based manipulations.

