Related Experiment Video
Updated: Jan 8, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
A fast method based on programmed temperature vaporization-mass spectrometry for the quantification of
Pablo Álvarez Alonso1, Iria González-Mariño1, Miguel Del Nogal Sánchez1
1Departamento de Química Analítica, Nutrición y Bromatología. Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain. mns@usal.es.
Abstract:
A rapid method has been developed for the determination of 17α-ethinylestradiol and drospirenone in contraceptive formulations. The method is based on the direct coupling of a programmed temperature vaporizer inlet to a quadrupole mass spectrometer via a deactivated fused silica tube (10 m × 0.18 mm) that is maintained at 275 °C throughout the entire analysis. The inlet is equipped with a baffled glass liner coated with Siltek™ and the injection is performed in split mode (ratio 1 : 10). The data acquisition time was only 1.0 min per sample, allowing for the high-throughput quantification of active principles in contraceptive pills in minimal time. The goal is to apply this strategy as a screening tool in quality control processes, limiting the use of the more costly and time-consuming chromatographic methods to those pills showing anomalous results, thus optimizing laboratory resources. Sample treatment involved a fast ultrasound-assisted solid-liquid extraction, and both sample preparation and instrumental conditions were optimized. The determination of the active principles was performed using the standard addition method. Accuracy, expressed as recovery percentage relative to the mass of active principle declared by the manufacturer, varied between 80% and 120%. Intra- and inter-day precision were adequate, with values of relative standard deviation (% RSD) equal to or less than 9% and 11%, respectively. Furthermore, the sustainability profile of the proposed rapid method was evaluated using the HEXAGON algorithm, which demonstrated that the PTV-MS method contributes to sustainable development by benefiting both the environment and society.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Volatilization
In Vitro Drug Dissolution: Compendial Testing Models II