Hybrid PET/MRI Imaging of Alzheimer's Disease Based on 18F-AV-1451
Published on: April 18, 2025
Alzheimer's Imaging Consortium
Autumn Shoebridge1, Beili Shao2,3, Abigail Rebecca Lee3
1University of Nottingham, Nottingham, Nottinghamshire, UK.
Background:
Diagnosing dementia can be challenging due to its multiple causes and overlapping presentations, especially in the early stages when cognitive impairment is mild, leading to misdiagnosis in clinical practice. Previous research assesses the use of neuroimaging for the diagnosis of Alzheimer's disease (AD). However, it is unclear whether these findings are replicable in real-world clinical practice and in non-AD dementia.
Method:
To explore the diagnostic accuracy of fluorodeoxyglucose (FDG)-positron emission tomography (PET) computed tomography (CT) of the brain by assessing the proportion of false negatives for different dementia diagnoses. FDG-PET CT scans and neuropsychological test scores from 155 participants aged between 36-82 (mean 62 years; 56% male) with Alzheimer's disease and related dementia (ADRD) were included in the analysis. Their clinical diagnosis of study participants was based on clinical and neuroradiological assessments and included longitudinal neurocognitive tests, Magnetic Resonance Imaging (MRI) of the brain, FDG-PET-CT of the brain, and the examination of cerebrospinal fluid (CSF) for amyloidβ, total tau and 181-Phsophorlyated-tau measurements. The data was obtained from CogNID (Cognitive and NeuroImaging in neurodegenerative Disorders, IRAS: 250525, ClinicalTrials.gov Identifier: NCT03861884), a prospective study inviting patients who are referred to a Nottingham tertiary referral centre from the Memory clinics in the East Midlands, and Cognitive Clinics at the Queen's Medical Centre.
Result:
The proportion of false negatives from FDG-PET ranged from 11-55%. The lowest proportion of false negatives was found in the Frontotemporal dementia diagnosis group, and the highest proportion of false negatives was found in the other neurodegeneration group. In early-onset dementia patients (N = 112), the proportion of false negatives ranged from 15-60%.
Conclusion:
FDG-PET-CT of the brain produces a notable proportion of false negatives in dementia workups, suggesting limitations in sensitivity. These findings indicate that FDG-PET-CT alone may not be sufficiently reliable for diagnostic use in clinical practice and should be complemented by additional diagnostic methods.
More Related Videos
09:31Visualization of Amyloid β Deposits in the Human Brain with Matrix-assisted Laser Desorption/Ionization Imaging Mass Spectrometry
Published on: March 7, 2019
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
Related Concept Videos
Alzheimer's Disease: Overview
The clinical diagnosis of AD hinges on the presence of memory and other cognitive impairments. Biomarkers, such as changes in Aβ...
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...