Clinical Evaluation of Intraoral, In-Lab Scanners and PVS Impression Materials Using STL Superimposition.
Nader Abdulhameed1, Inessa Slipak2, Alexandra Manibo2
1Restorative Dental Sciences, College of Dentistry, University of Florida, Gainesville, FL 32610, USA.
Dentistry Journal
|December 24, 2025
Summary
Intraoral scanners and in-lab scanners show comparable scan quality for removable complete dentures. Heavy and light body polyvinyl siloxane impression materials offer superior accuracy compared to medium and light body, comparable to intraoral scanners.
Area of Science:
- Dental Materials Science
- Digital Dentistry
- Prosthodontics
Background:
- Accurate impressions are crucial for fabricating removable complete dentures (RCD).
- The accuracy of digital impressions using intraoral scanners (IOS) versus traditional in-lab scanning of polyvinyl siloxane (PVS) impressions is an area of ongoing research.
- Understanding the dimensional stability of different PVS impression materials is vital for clinical success.
Purpose of the Study:
- To compare the accuracy of intraoral scanners (IOS) against in-lab scanners for RCD.
- To evaluate the accuracy differences between two types of PVS impression materials.
- To assess the accuracy of PVS impression materials compared to IOS.
Main Methods:
- Fourteen subjects received maxillary and mandibular RCD.
- Impressions were made using heavy/light (HL) or medium/light (ML) body PVS materials.
- Impressions were scanned using IOS (Trios, Omnicam) and an in-lab scanner; STL files were analyzed for gap measurements at 60 points.
Main Results:
- No significant difference in accuracy between Trios and Omnicam IOS (44 ± 10 μm).
- Significant differences were found between Trios and in-lab scans (62 ± 21 μm), and between ML and Trios (66 ± 24 μm) and HL and ML PVS groups (50 ± 21 μm).
- No significant difference was observed between HL PVS and Trios IOS (37 ± 10 μm).
Conclusions:
- Intraoral scanners demonstrate comparable scan quality.
- The choice of PVS impression material significantly impacts the accuracy of in-lab scans.
- Heavy and light body PVS materials provide accurate and dimensionally stable impressions for complete dentures, comparable to IOS.
Related Concept Videos
Imaging Studies I: CT and MRI
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
The most common cardiovascular diagnostic test is an X-ray. It produces images of the heart, blood vessels, and adjacent structures.
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...