Related Experiment Video
Updated: Jun 15, 2026

Ratiometric Imaging of Extracellular pH in Dental Biofilms
Published on: March 9, 2016
Quantification of Bisphenol A in the Saliva of Patients Wearing Clear Aligners
Andrea Vitores-Calero1, Verónica García-Sanz1, Vanessa Paredes-Gallardo1
1Department of Orthodontics, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
Abstract:
Background/Objectives: To analyze the behavior and release of bisphenol A (BPA) in the saliva of patients wearing clear aligners, and to evaluate differences in BPA levels between patients treated with aligners from the market-leading brand and those treated with in-office aligners. For the in-office group, 0.762 mm (0.30") thick thermoforming sheets from Ortolan® were used to fabricate the aligners. Methods: Patients about to begin orthodontic treatment with clear aligners in the Master's degree program in Orthodontics at the University of Valencia were recruited for this prospective observational study. Patients were divided into two groups based on the type of aligners: The Invisalign® group and the In-Office aligner group. Four saliva samples were taken from each patient at different times during treatment, with a one-week follow-up. The samples were stored at -80 °C and analyzed using mass spectrometry. Results: A total of 24 patients were included in the study, with 12 patients in each group. A statistically significant difference was found between baseline BPA levels and the increase observed half an hour after bonding the attachments. After a week, values returned to pre-treatment levels. Furthermore, BPA levels changed significantly during the follow-up period and were similar in both groups. Conclusions: An immediate increase was observed when the attachments were bonded with both treatments; however, differentiation from the 'peak' and recovery to baseline values was faster in patients treated with In-Office aligners. In those treated with Invisalign®, after the placement of the aligners, values recorded were not significantly different from baseline, nor from the previous peak.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant