Related Experiment Video
Updated: Jan 7, 2026

Coupling Carbon Capture from a Power Plant with Semi-automated Open Raceway Ponds for Microalgae Cultivation
Published on: August 14, 2020
Study on Specific Energy Consumption of Rotating Dynamic Filtration for Ship EGC Desulfurization Wastewater Treatment
Shiyong Wang1,2,3,4, Baohua Yang5, Juan Wu2
1Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China.
Abstract:
In recent decades, rotating dynamic filtration (RDF) has attracted considerable attention due to its high efficiency and low energy consumption. While most studies have focused on separation behavior and membrane fouling, energy consumption in RDF has received limited attention. This study investigates the specific energy consumption (SEC) of the RDF process for ship exhaust gas cleaning (EGC) desulfurization wastewater treatment and proposes an optimization method based on both energy consumption and equipment cost. The total SEC increases with rotational velocity, circulation flow, feed concentration, and membrane size but decreases with temperature and remains unaffected by the number of membrane elements. In RDF, the total SEC is only 9.05-19.29% of that in tubular cross-flow filtration (CFF) at equivalent shear force ranging from 3.86 Pa to 121.14 Pa. Operating energy and investment costs are primarily determined by the number of membrane elements and the rotational velocity. According to the economic analysis, the lowest treatment cost for EGC wastewater is CNY 6.09 per cubic meter for a 5 m3·h-1 capacity, using 84 membrane elements (374 mm, 0.2 µm) at a rotational velocity of 200 rpm, an operating pressure of 200 kPa, and a temperature of 40 °C.