Related Experiment Video
Updated: Jun 18, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Validated Matrix Matched Quantification of Ethyl Chloride in Postmortem Biological Samples Using HS-GC-FID: Lung as
Halit Canberk Aydogan1, Ali Rıza Tümer2, Ramazan Akçan2
1Department of Forensic Medicine, Ordu University Training and Research Hospital, Ordu 52200, Türkiye.
Abstract:
Ethyl chloride, a volatile anesthetic with high abuse potential, remains forensically undercharacterized postmortem. In an inhalation model (n = 30), male Wistar rats were exposed to 86,000 ppm ethyl chloride under real-time PID monitoring; blood, lung, liver and brain (plus exploratory adipose, kidney, muscle) were sampled at 0, 2, 4, 6 and 12 h postmortem. A matrix-matched HS-GC-FID method was validated (Eurochem): linearity (R2 = 0.9947-0.9965), LOD 0.01-0.02 ng/μL, LOQ 0.04-0.06 ng/μL, precision RSD 3.9-5.1%, recovery 90-104%, full selectivity against common volatiles. Lung yielded the highest concentrations overall; a significant decline occurred in lung between 2 h and 4 h (Pillai's Trace p = 0.034). Concentrations became increasingly irregular ≥6 h across tissues. Early autopsy sampling, preferably within ≤6 h, optimizes ethyl chloride detectability. The validated matrix-matched HS-GC-FID protocol provides a cost-effective, robust alternative to MS platforms for volatile screening in routine forensic practice and supports prioritizing lung for analysis.
More Related Videos
12:15Quantification of three DNA Lesions by Mass Spectrometry and Assessment of Their Levels in Tissues of Mice Exposed to Ambient Fine Particulate Matter
Published on: May 29, 2019
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II