External Quality Assessment for Unfractionated Heparin Monitoring: An Update from Australasia/Asia-Pacific

Emmanuel J Favaloro1,2,3,4, Sandya Arunachalam5, Leonardo Pasalic1,2,6

  • 1Department of Haematology, Sydney Centres for Thrombosis and Haemostasis, Institute of Clinical Pathology and Medical Research, Westmead Hospital, Westmead, NSW, Australia.

PubMed

Unfractionated heparin (UFH) remains a major anticoagulant therapy applied within the acute hospital system. Due to intra- and interpatient variability, UFH monitoring needs to be applied to ensure patients remain free of thrombotic and bleeding complications at too low and too high an UFH level, respectively. Monitoring of UFH therapy is usually achieved using either an activated partial thromboplastin time (aPTT) or an anti-factor Xa (anti-Xa) method. The former is a clotting assay that evaluates both the anti-factor IIa (anti-IIa or anti-thrombin) and anti-Xa anticoagulant activity of UFH and the latter is a chromogenic assay that evaluates just the anti-Xa anticoagulant activity of UFH. The aPTT method is perhaps more widely utilized since aPTT testing is performed by all hemostasis laboratories performing routine coagulation tests. However, the aPTT method requires establishment of an aPTT UFH therapeutic range. The anti-Xa method is favored in larger hospital sites and by most experts and uses a standard UFH therapeutic range. We report findings for aPTT and anti-Xa testing for UFH monitoring in our geographic region using recent data (testing for the past 5 years; 2020-2024 inclusive) from the Royal College of Pathologists of Australasia Quality Assurance Program, an international external quality assessment (EQA) program, with over 110 enrolments for this EQA module. Four samples are assessed each year, with these comprising various levels of UFH. Good reproducibility was observed for duplicate samples sent in different surveys. Coefficient of variation (%) data revealed moderate variation for samples containing UFH (10-40% for anti-Xa; 10-25% for aPTT). Anti-Xa reagents containing dextran sulphate tended to yield higher anti-Xa values than those without. Interpretations regarding UFH levels being below, within, or above therapeutic levels were generally reported as expected, according to the level of UFH present in the sample, especially for anti-Xa testing.

Related Concept Videos

Anticoagulant Drugs: Low-Molecular-Weight Heparins01:30

Anticoagulant Drugs: Low-Molecular-Weight Heparins

Hemostasis is a crucial process that prevents excessive blood loss from damaged blood vessels. It involves various mechanisms such as vasoconstriction, platelet adhesion and activation, and fibrin formation. The importance of each mechanism depends on the type of vessel injury. In contrast, thrombosis is the abnormal formation of a blood clot within the blood vessels, leading to potential complications if the clot obstructs blood flow. Thrombosis can be caused by increased coagulability of the...
1.6K
Venous Thrombosis III: Interprofessional Care01:29

Venous Thrombosis III: Interprofessional Care

Venous thrombosis requires effective prevention and treatment strategies to improve patient outcomes and reduce potential complications.Prevention StrategiesHealthcare providers must prioritize preventing venous thromboembolism (VTE) for all adult patients upon admission. Interventions depend on bleeding and thrombosis risk, medical history, current medications, diagnoses, planned procedures, and patient preferences. Patients on bed rest should change positions every two hours and, if not...
257
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care01:29

Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care

Diagnosing Pulmonary EmbolismDiagnosing pulmonary embolism (PE) involves clinical assessment and advanced imaging tests. The preferred diagnostic tool is the spiral (helical) CT scan or CT angiography (CTA), which uses intravenous contrast media to visualize the pulmonary vasculature and identify emboli.A ventilation-perfusion (V/Q) scan is an alternative for patients unable to receive contrast media. This scan includes both perfusion and ventilation scanning. Perfusion scanning involves...
274
Therapeutic Drug Monitoring: Drug Analysis Methods01:26

Therapeutic Drug Monitoring: Drug Analysis Methods

Therapeutic Drug Monitoring (TDM) is a clinical practice that measures specific drug levels in a patient's blood or body tissues to tailor drug therapy effectively. This monitoring is critical for managing drugs with narrow therapeutic indices like digoxin and phenytoin, ensuring they are both safe and effective. For instance, monitoring theophylline levels in asthma patients involves precision and sensitivity to adjust doses according to individual responses to therapy, ensuring efficacy and...
157