Related Experiment Video
Updated: Jan 7, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Fluoroless Implantation of Pacemaker and Cardioverter-Defibrillator Using Ultrasound As An Imaging Tool: A
Habib Rehman Khan1, Samuel Triemstra2, Abbie Pardo2
1London Health Sciences Centre, Schulich School of Medical and Dentistry, University of Western Ontario, London, Ontario, Canada. Electronic address: http://www.twitter.com/Dr_Habib_Khan.
Background:
Cardiac implantable electronic device (CIED) implantation requires fluoroscopy and is associated with procedural complications, including pneumothorax, lead dislodgement, cardiac perforation, lead-associated tricuspid regurgitation, and radiation risk for patients and operators. The efficacy and safety of ultrasound-guided CIED implantation need to be determined.
Methods:
A prospective, nonrandomized, multioperator, single-centre study enrolled patients requiring a single-chamber CIED. The primary efficacy endpoint was successful single-chamber CIED implantation with < 20 seconds of fluoroscopy time. The efficacy objective is met if the lower boundary of the 1-sided 97.5% confidence interval (CI) for percentage of patients with successful implantation is > 75%. The primary safety endpoint was freedom from procedural complications at 12 months and was met if the lower boundary of the 1-sided 97.5% CI for percentage of patients free from procedural complications was > 85%.
Results:
A total of 69 patients received CIEDs, with a mean age of 80.4 ± 13.4 years (95% CI = 76.4-83.0). The percentage of patients with successful device implantation in < 20 seconds of fluoroscopy was 87% (lower bound of 1-sided 97.5% CI = 77.5, P = 0.01). The Kaplan-Meier estimate of percentage of patients free from complications was 94.2% (lower bound of 86.8% for the 1-sided 97.5% CI, P < 0.01). One lead dislodgement and 3 cases of lead-related worsening tricuspid regurgitation occurred during 12 months of follow-up. The mean procedural time was 64.3 ± 20.3 (95% CI = 59.4-69.2) minutes. The median fluoroscopic duration was 6 seconds (interquartile range = 2-11).
Conclusions:
In this study, we found that ultrasound guidance for implanting single-chamber CIEDs is efficacious and safe. Larger randomized controlled trials are needed to substantiate these observations.
Clinical Trial Registration:
NCT04858698.
More Related Videos
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...