Published on: October 24, 2019
Unambiguous analytical separation and improved syntheses of [11C]acetate and [11C]acetoacetate
Karsten Bamminger1, Lukas Nics2, Marcus Hacker2
1Division of Nuclear Medicine 3L, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Waehringer Guertel 18-20, Vienna, Austria. karsten.bamminger@meduniwien.ac.at.
Background:
[11C]Acetate and [11C]acetoacetate are PET radiotracers widely used to assess oxidative metabolism and ketone body utilization, respectively. This study aimed to establish robust, high-yield syntheses of both tracers using a GE TRACERlab FX2 C module, with an emphasis on improving radiochemical purity (RCP), radiochemical yield (RCY), optimizing operational parameters, and developing accurate quality control methods. [11C]Acetate was synthesized via Grignard carboxylation using [11C]CO2 and purified with a cartridge-based system. [11C]Acetoacetate was produced via in-loop [11C]CO2 carboxylation of a lithium enolate precursor, followed by semi-preparative reversed-phase HPLC purification. Quality control was performed by reported ion-exchange chromatography (IEX-HPLC) and novel reversed-phase HPLC (RP-HPLC). A systematic literature review was conducted to evaluate prior quality control methods for [11C]acetoacetate.
Results:
Omission of helium flow during [11C]CO2 trap bake-out significantly improved activity recovery from the [11C]CO2 trap (from 63 to 89%) and reduced release time (from 4.8 to 3.1 min). [11C]Acetate and [11C]acetoacetate were synthesized with mean isolated activities of 30.2 GBq and 3.24 GBq and mean RCPs of 96.9% and 97.1%, respectively. The final formulations met all European Pharmacopoeia criteria. While the widely-used IEX-HPLC method failed to differentiate [11C]acetate from [11C]acetoacetate, the newly-developed RP-HPLC method enabled unambiguous separation. Literature analysis revealed that most published studies on [11C]acetoacetate likely overlooked [11C]acetate as a radiochemical impurity due to insufficient analytical separation.
Conclusions:
Reliable synthesis protocols for [11C]acetate and [11C]acetoacetate were established on the GE TRACERlab FX2 C, with significant improvements in [11C]CO2 handling and product purification. Inclusion of the proposed RP-HPLC method enables a more accurate and specific assessment of RCP compared to IEX-HPLC alone and should be considered for a valid quality control of [11C]acetoacetate.
More Related Videos
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Alkylation of β-Ketoester Enolates: Acetoacetic Ester Synthesis

![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)